{"id":"CVE-2024-23795","state":"PUBLISHED","title":"A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant Simulation V2302 (All versions < V2302.0006). The affected ap","description":"A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant Simulation V2302 (All versions < V2302.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process.","publishedAt":"2024-02-13T09:00:09.340Z","updatedAt":"2025-05-09T18:26:57.002Z","severity":{"score":7.8,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","source":"siemens"},"assigner":"siemens","products":["Siemens Tecnomatix Plant Simulation V2201","Siemens Tecnomatix Plant Simulation V2302"],"affected":[{"vendor":"Siemens","product":"Tecnomatix Plant Simulation V2201","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2201.0012","versionType":"custom"}]},{"vendor":"Siemens","product":"Tecnomatix Plant Simulation V2302","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2302.0006","versionType":"custom"}]}],"references":["https://cert-portal.siemens.com/productcert/html/ssa-017796.html"],"weaknesses":["CWE-787"],"ingestedAt":"2026-10-29T20:06:59.846Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/23xxx/CVE-2024-23795.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-23795","state":"PUBLISHED","datePublished":"2024-02-13T09:00:09.340Z","dateUpdated":"2025-05-09T18:26:57.002Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2024-01-22T10:34:49.955Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant Simulation V2302 (All versions < V2302.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process."}],"affected":[{"vendor":"Siemens","product":"Tecnomatix Plant Simulation V2201","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2201.0012","versionType":"custom"}]},{"vendor":"Siemens","product":"Tecnomatix Plant Simulation V2302","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2302.0006","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-017796.html"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","baseScore":7.8,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-787","lang":"en","description":"CWE-787: Out-of-bounds Write","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2024-02-13T09:00:09.340Z"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-017796.html","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-01T23:13:08.435Z"}},{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-05-08T15:45:37.675034Z","id":"CVE-2024-23795","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-05-09T18:26:57.002Z"}}]}}}