{"id":"CVE-2024-11983","state":"PUBLISHED","title":"Billion Electric router - OS Command Injection","description":"Certain models of routers from Billion Electric has an OS Command Injection vulnerability, allowing remote attackers with administrator privileges to inject arbitrary system commands into a specific SSH function and execute them on the device.","publishedAt":"2024-11-29T06:57:24.047Z","updatedAt":"2024-11-29T14:10:39.561Z","severity":{"score":7.2,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","source":"twcert"},"assigner":"twcert","products":["Billion Electric M100","Billion Electric M150","Billion Electric M120N","Billion Electric M500"],"affected":[{"vendor":"Billion Electric","product":"M100","defaultStatus":"unaffected","versions":[{"version":"1.04.1.592.*","status":"affected","lessThan":"1.04.1.592.8","versionType":"custom"},{"version":"1.04.1.613.*","status":"affected","lessThan":"1.04.1.613.13","versionType":"custom"},{"version":"1.04.1.*","status":"affected","lessThan":"1.04.1.675","versionType":"custom"}]},{"vendor":"Billion Electric","product":"M150","defaultStatus":"unaffected","versions":[{"version":"1.04.1.592.*","status":"affected","lessThan":"1.04.1.592.8","versionType":"custom"},{"version":"1.04.1.613.*","status":"affected","lessThan":"1.04.1.613.13","versionType":"custom"},{"version":"1.04.1.*","status":"affected","lessThan":"1.04.1.675","versionType":"custom"}]},{"vendor":"Billion Electric","product":"M120N","defaultStatus":"unaffected","versions":[{"version":"1.04.1.592.*","status":"affected","lessThan":"1.04.1.592.8","versionType":"custom"},{"version":"1.04.1.613.*","status":"affected","lessThan":"1.04.1.613.13","versionType":"custom"},{"version":"1.04.1.*","status":"affected","lessThan":"1.04.1.675","versionType":"custom"}]},{"vendor":"Billion Electric","product":"M500","defaultStatus":"unaffected","versions":[{"version":"1.04.1.592.*","status":"affected","lessThan":"1.04.1.592.8","versionType":"custom"},{"version":"1.04.1.613.*","status":"affected","lessThan":"1.04.1.613.13","versionType":"custom"},{"version":"1.04.1.*","status":"affected","lessThan":"1.04.1.675","versionType":"custom"}]}],"references":["https://www.twcert.org.tw/tw/cp-132-8279-bf67e-1.html","https://www.twcert.org.tw/en/cp-139-8280-ae6e1-2.html"],"weaknesses":["CWE-78"],"ingestedAt":"2026-10-29T20:06:50.777Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/11xxx/CVE-2024-11983.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-11983","state":"PUBLISHED","datePublished":"2024-11-29T06:57:24.047Z","dateUpdated":"2024-11-29T14:10:39.561Z","assignerShortName":"twcert","assignerOrgId":"cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e","dateReserved":"2024-11-29T01:52:22.084Z"},"containers":{"cna":{"title":"Billion Electric router - OS Command Injection","descriptions":[{"lang":"en","value":"Certain models of routers from Billion Electric has an OS Command Injection vulnerability, allowing remote attackers with administrator privileges to inject arbitrary system commands into a specific SSH function and execute them on the device."}],"affected":[{"vendor":"Billion Electric","product":"M100","defaultStatus":"unaffected","versions":[{"version":"1.04.1.592.*","status":"affected","lessThan":"1.04.1.592.8","versionType":"custom"},{"version":"1.04.1.613.*","status":"affected","lessThan":"1.04.1.613.13","versionType":"custom"},{"version":"1.04.1.*","status":"affected","lessThan":"1.04.1.675","versionType":"custom"}]},{"vendor":"Billion Electric","product":"M150","defaultStatus":"unaffected","versions":[{"version":"1.04.1.592.*","status":"affected","lessThan":"1.04.1.592.8","versionType":"custom"},{"version":"1.04.1.613.*","status":"affected","lessThan":"1.04.1.613.13","versionType":"custom"},{"version":"1.04.1.*","status":"affected","lessThan":"1.04.1.675","versionType":"custom"}]},{"vendor":"Billion Electric","product":"M120N","defaultStatus":"unaffected","versions":[{"version":"1.04.1.592.*","status":"affected","lessThan":"1.04.1.592.8","versionType":"custom"},{"version":"1.04.1.613.*","status":"affected","lessThan":"1.04.1.613.13","versionType":"custom"},{"version":"1.04.1.*","status":"affected","lessThan":"1.04.1.675","versionType":"custom"}]},{"vendor":"Billion Electric","product":"M500","defaultStatus":"unaffected","versions":[{"version":"1.04.1.592.*","status":"affected","lessThan":"1.04.1.592.8","versionType":"custom"},{"version":"1.04.1.613.*","status":"affected","lessThan":"1.04.1.613.13","versionType":"custom"},{"version":"1.04.1.*","status":"affected","lessThan":"1.04.1.675","versionType":"custom"}]}],"references":[{"url":"https://www.twcert.org.tw/tw/cp-132-8279-bf67e-1.html","tags":["third-party-advisory"]},{"url":"https://www.twcert.org.tw/en/cp-139-8280-ae6e1-2.html","tags":["third-party-advisory"]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.2,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-78","description":"CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"twcert","orgId":"cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e","dateUpdated":"2024-11-29T06:57:24.047Z"},"datePublic":"2024-11-29T06:53:00.000Z","impacts":[{"capecId":"CAPEC-88","descriptions":[{"lang":"en","value":"CAPEC-88 OS Command Injection"}]}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"For firmware version 1.04.1.592.x, please update to 1.04.1.592.8 or later.<br>For firmware version 1.04.1.613.x, please update to 1.04.1.613.13 or later.<br>For all other firmware version 1.04.1.x, please update to 1.04.1.675 or later.<br>"}],"value":"For firmware version 1.04.1.592.x, please update to 1.04.1.592.8 or later.\nFor firmware version 1.04.1.613.x, please update to 1.04.1.613.13 or later.\nFor all other firmware version 1.04.1.x, please update to 1.04.1.675 or later."}],"source":{"advisory":"TVN-202411028","discovery":"EXTERNAL"},"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"billion_electric","product":"m100","defaultStatus":"unknown","versions":[{"version":"1.04.1.592.*","status":"affected","lessThan":"1.04.1.592.8","versionType":"custom"},{"version":"1.04.1.613.*","status":"affected","lessThan":"1.04.1.613.13","versionType":"custom"},{"version":"1.04.1.*","status":"affected","lessThan":"1.04.1.675","versionType":"custom"}],"cpes":["cpe:2.3:a:billion_electric:m100:*:*:*:*:*:*:*:*"]},{"vendor":"billion_electric","product":"m150","defaultStatus":"unknown","versions":[{"version":"1.04.1.592.*","status":"affected","lessThan":"1.04.1.592.8","versionType":"custom"},{"version":"1.04.1.613.*","status":"affected","lessThan":"1.04.1.613.13","versionType":"custom"},{"version":"1.04.1.* <","status":"affected","lessThan":"1.04.1.675","versionType":"custom"}],"cpes":["cpe:2.3:a:billion_electric:m150:*:*:*:*:*:*:*:*"]},{"vendor":"billion_electric","product":"m120n","defaultStatus":"unknown","versions":[{"version":"1.04.1.592.*","status":"affected","lessThan":"1.04.1.592.8","versionType":"custom"},{"version":"1.04.1.613.*","status":"affected","lessThan":"1.04.1.613.13","versionType":"custom"},{"version":"1.04.1.* <","status":"affected","lessThan":"1.04.1.675","versionType":"custom"}],"cpes":["cpe:2.3:a:billion_electric:m120n:*:*:*:*:*:*:*:*"]},{"vendor":"billion_electric","product":"m500","defaultStatus":"unknown","versions":[{"version":"1.04.1.592.*","status":"affected","lessThan":"1.04.1.592.8","versionType":"custom"},{"version":"1.04.1.613.*","status":"affected","lessThan":"1.04.1.613.13","versionType":"custom"},{"version":"1.04.1.* <","status":"affected","lessThan":"1.04.1.675","versionType":"custom"}],"cpes":["cpe:2.3:a:billion_electric:m500:*:*:*:*:*:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-11-29T13:57:51.182205Z","id":"CVE-2024-11983","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-11-29T14:10:39.561Z"}}]}}}