{"id":"CVE-2024-11665","state":"PUBLISHED","title":"Unauthenticated Remote Command Injection","description":"Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in hardy-barth cph2_echarge_firmware allows OS Command Injection.This issue affects cph2_echarge_firmware: through 2.0.4.","publishedAt":"2024-11-24T22:32:43.427Z","updatedAt":"2024-11-25T01:30:24.409Z","severity":{"score":8.8,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","source":"ONEKEY"},"assigner":"ONEKEY","products":["hardy-barth cph2_echarge_firmware"],"affected":[{"vendor":"hardy-barth","product":"cph2_echarge_firmware","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"2.0.4","versionType":"semver"}]}],"references":["https://www.onekey.com/resource/critical-vulnerabilities-in-ev-charging-stations-analysis-of-echarge-controllers"],"weaknesses":["CWE-77"],"ingestedAt":"2026-10-29T20:06:50.777Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/11xxx/CVE-2024-11665.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-11665","state":"PUBLISHED","datePublished":"2024-11-24T22:32:43.427Z","dateUpdated":"2024-11-25T01:30:24.409Z","assignerShortName":"ONEKEY","assignerOrgId":"2d533b80-6e4a-4e20-93e2-171235122846","dateReserved":"2024-11-24T22:27:15.904Z"},"containers":{"cna":{"title":"Unauthenticated Remote Command Injection","descriptions":[{"lang":"en","value":"Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in hardy-barth cph2_echarge_firmware allows OS Command Injection.This issue affects cph2_echarge_firmware: through 2.0.4."}],"affected":[{"vendor":"hardy-barth","product":"cph2_echarge_firmware","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"2.0.4","versionType":"semver"}]}],"references":[{"url":"https://www.onekey.com/resource/critical-vulnerabilities-in-ev-charging-stations-analysis-of-echarge-controllers","tags":["third-party-advisory"]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"ADJACENT_NETWORK","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-77","description":"CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"ONEKEY","orgId":"2d533b80-6e4a-4e20-93e2-171235122846","dateUpdated":"2024-11-24T23:18:51.581Z"},"credits":[{"lang":"en","type":"finder","value":"Quentin Kaiser from ONEKEY Research Labs"}],"datePublic":"2024-11-24T07:00:00.000Z","impacts":[{"capecId":"CAPEC-88","descriptions":[{"lang":"en","value":"CAPEC-88 OS Command Injection"}]}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"hardy-barth","product":"cph2_echarge_firmware","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"2.0.4","versionType":"semver"}],"cpes":["cpe:2.3:o:hardy-barth:cph2_echarge_firmware:*:*:*:*:*:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-11-25T01:30:19.320887Z","id":"CVE-2024-11665","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-11-25T01:30:24.409Z"}}]}}}