{"id":"CVE-2024-10774","state":"PUBLISHED","title":"SICK InspectorP61x and SICK InspectorP62x have unauthenticated CROWN APIs","description":"Unauthenticated CROWN APIs allow access to critical functions. This leads to the accessibility of large parts of the web application without authentication.","publishedAt":"2024-12-06T12:35:03.327Z","updatedAt":"2024-12-09T14:48:43.228Z","severity":{"score":7.3,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L","source":"SICK AG"},"assigner":"SICK AG","products":["SICK AG SICK InspectorP61x","SICK AG SICK InspectorP62x"],"affected":[{"vendor":"SICK AG","product":"SICK InspectorP61x","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"<5.0.0","versionType":"custom"}]},{"vendor":"SICK AG","product":"SICK InspectorP62x","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"<5.0.0","versionType":"custom"}]}],"references":["https://sick.com/psirt","https://cdn.sick.com/media/docs/1/11/411/Special_information_CYBERSECURITY_BY_SICK_en_IM0084411.PDF","https://www.cisa.gov/resources-tools/resources/ics-recommended-practices","https://www.first.org/cvss/calculator/3.1","https://www.sick.com/.well-known/csaf/white/2024/sca-2024-0006.pdf","https://www.sick.com/.well-known/csaf/white/2024/sca-2024-0006.json"],"weaknesses":["CWE-306"],"ingestedAt":"2026-10-29T20:06:50.777Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/10xxx/CVE-2024-10774.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-10774","state":"PUBLISHED","datePublished":"2024-12-06T12:35:03.327Z","dateUpdated":"2024-12-09T14:48:43.228Z","assignerShortName":"SICK AG","assignerOrgId":"a6863dd2-93fc-443d-bef1-79f0b5020988","dateReserved":"2024-11-04T13:07:02.373Z"},"containers":{"cna":{"title":"SICK InspectorP61x and SICK InspectorP62x have unauthenticated CROWN APIs","descriptions":[{"lang":"en","value":"Unauthenticated CROWN APIs allow access to critical functions. This leads to the accessibility of large parts of the web application without authentication."}],"affected":[{"vendor":"SICK AG","product":"SICK InspectorP61x","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"<5.0.0","versionType":"custom"}]},{"vendor":"SICK AG","product":"SICK InspectorP62x","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"<5.0.0","versionType":"custom"}]}],"references":[{"url":"https://sick.com/psirt","tags":["x_SICK PSIRT Website"]},{"url":"https://cdn.sick.com/media/docs/1/11/411/Special_information_CYBERSECURITY_BY_SICK_en_IM0084411.PDF","tags":["x_SICK Operating Guidelines"]},{"url":"https://www.cisa.gov/resources-tools/resources/ics-recommended-practices","tags":["x_ICS-CERT recommended practices on Industrial Security"]},{"url":"https://www.first.org/cvss/calculator/3.1","tags":["x_CVSS v3.1 Calculator"]},{"url":"https://www.sick.com/.well-known/csaf/white/2024/sca-2024-0006.pdf","tags":["vendor-advisory"]},{"url":"https://www.sick.com/.well-known/csaf/white/2024/sca-2024-0006.json","tags":["vendor-advisory","x_csaf"]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"LOW","baseScore":7.3,"baseSeverity":"HIGH","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-306","description":"CWE-306 Missing Authentication for Critical Function","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"SICK AG","orgId":"a6863dd2-93fc-443d-bef1-79f0b5020988","dateUpdated":"2024-12-06T12:35:03.327Z"},"credits":[{"lang":"en","type":"finder","value":"Manuel Stotz"},{"lang":"en","type":"finder","value":"Tobias Jaeger"}],"datePublic":"2024-12-06T12:00:00.000Z","source":{"advisory":"SCA-2024-0006","discovery":"EXTERNAL"},"workarounds":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"For InspectorP61x and InspectorP62x: \n\nCustomers are strongly recommended to upgrade to the latest release. Furthermore, the\napp development for which the CROWN API is required should be done in a trusted environment. As\nsoon as the device is used productively with the custom-developed apps, the CROWN API should be\ndeactivated."}],"value":"For InspectorP61x and InspectorP62x: \n\nCustomers are strongly recommended to upgrade to the latest release. Furthermore, the\napp development for which the CROWN API is required should be done in a trusted environment. As\nsoon as the device is used productively with the custom-developed apps, the CROWN API should be\ndeactivated."}],"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"sick","product":"inspector61x_firmware","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"5.0.0","versionType":"custom"}],"cpes":["cpe:2.3:o:sick:inspector61x_firmware:-:*:*:*:*:*:*:*"]},{"vendor":"sick","product":"inspector62x_firmware","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"5.0.0","versionType":"custom"}],"cpes":["cpe:2.3:o:sick:inspector62x_firmware:-:*:*:*:*:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-12-09T14:47:57.127996Z","id":"CVE-2024-10774","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-12-09T14:48:43.228Z"}}]}}}