{"id":"CVE-2024-10283","state":"PUBLISHED","title":"Tenda RX9/RX9 Pro SetNetControlList sub_4337EC stack-based overflow","description":"A vulnerability, which was classified as critical, has been found in Tenda RX9 and RX9 Pro 22.03.02.20. Affected by this issue is the function sub_4337EC of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.","publishedAt":"2024-10-23T15:00:12.454Z","updatedAt":"2024-10-23T17:33:05.674Z","severity":{"score":8.7,"label":"High","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","source":"VulDB"},"assigner":"VulDB","products":["Tenda RX9","Tenda RX9 Pro"],"affected":[{"vendor":"Tenda","product":"RX9","versions":[{"version":"22.03.02.20","status":"affected"}]},{"vendor":"Tenda","product":"RX9 Pro","versions":[{"version":"22.03.02.20","status":"affected"}]}],"references":["https://vuldb.com/?id.281558","https://vuldb.com/?ctiid.281558","https://vuldb.com/?submit.427064","https://gitee.com/GXB0_0/iot-vul/blob/master/Tenda/RX9/20/SetNetControlList.md","https://www.tenda.com.cn/"],"weaknesses":["CWE-121"],"ingestedAt":"2026-10-29T20:06:50.777Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/10xxx/CVE-2024-10283.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-10283","state":"PUBLISHED","datePublished":"2024-10-23T15:00:12.454Z","dateUpdated":"2024-10-23T17:33:05.674Z","assignerShortName":"VulDB","assignerOrgId":"1af790b2-7ee1-4545-860a-a788eba489b5","dateReserved":"2024-10-23T06:07:52.411Z"},"containers":{"cna":{"title":"Tenda RX9/RX9 Pro SetNetControlList sub_4337EC stack-based overflow","descriptions":[{"lang":"en","value":"A vulnerability, which was classified as critical, has been found in Tenda RX9 and RX9 Pro 22.03.02.20. Affected by this issue is the function sub_4337EC of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."},{"lang":"de","value":"Eine kritische Schwachstelle wurde in Tenda RX9 and RX9 Pro 22.03.02.20 entdeckt. Betroffen davon ist die Funktion sub_4337EC der Datei /goform/SetNetControlList. Mit der Manipulation des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei über das Netzwerk erfolgen. Der Exploit steht zur öffentlichen Verfügung."}],"affected":[{"vendor":"Tenda","product":"RX9","versions":[{"version":"22.03.02.20","status":"affected"}]},{"vendor":"Tenda","product":"RX9 Pro","versions":[{"version":"22.03.02.20","status":"affected"}]}],"references":[{"url":"https://vuldb.com/?id.281558","name":"VDB-281558 | Tenda RX9/RX9 Pro SetNetControlList sub_4337EC stack-based overflow","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.281558","name":"VDB-281558 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.427064","name":"Submit #427064 | Tenda RX9 Router RX9 Pro Firmware V22.03.02.20 Stack-based Buffer Overflow","tags":["third-party-advisory"]},{"url":"https://gitee.com/GXB0_0/iot-vul/blob/master/Tenda/RX9/20/SetNetControlList.md","tags":["exploit"]},{"url":"https://www.tenda.com.cn/","tags":["product"]}],"metrics":[{"cvssV4_0":{"version":"4.0","baseScore":8.7,"vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","baseSeverity":"HIGH"}},{"cvssV3_1":{"version":"3.1","baseScore":8.8,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV3_0":{"version":"3.0","baseScore":8.8,"vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV2_0":{"version":"2.0","baseScore":9,"vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-121","type":"CWE","lang":"en","description":"Stack-based Buffer Overflow"}]}],"providerMetadata":{"shortName":"VulDB","orgId":"1af790b2-7ee1-4545-860a-a788eba489b5","dateUpdated":"2024-10-23T15:00:12.454Z"},"timeline":[{"time":"2024-10-23T00:00:00.000Z","lang":"en","value":"Advisory disclosed"},{"time":"2024-10-23T02:00:00.000Z","lang":"en","value":"VulDB entry created"},{"time":"2024-10-23T08:12:57.000Z","lang":"en","value":"VulDB entry last update"}],"credits":[{"lang":"en","value":"GuoXB (VulDB User)","type":"reporter"}]},"adp":[{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"tenda","product":"rx9_pro","defaultStatus":"unknown","versions":[{"version":"22.03.02.20","status":"affected"}],"cpes":["cpe:2.3:h:tenda:rx9_pro:-:*:*:*:*:*:*:*"]},{"vendor":"tenda","product":"rx9","defaultStatus":"unknown","versions":[{"version":"22.03.02.20","status":"affected"}],"cpes":["cpe:2.3:a:tenda:rx9:*:*:*:*:*:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-10-23T17:30:46.351880Z","id":"CVE-2024-10283","options":[{"Exploitation":"poc"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-10-23T17:33:05.674Z"}}]}}}