{"id":"CVE-2024-0865","state":"PUBLISHED","title":"CWE-798: Use of hard-coded credentials vulnerability exists that could cause local privilege","description":"CWE-798: Use of hard-coded credentials vulnerability exists that could cause local privilege\nescalation when logged in as a non-administrative user.","publishedAt":"2024-06-12T17:23:00.908Z","updatedAt":"2024-08-01T18:18:18.824Z","severity":{"score":7.8,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","source":"schneider"},"assigner":"schneider","products":["Schneider Electric EcoStruxure IT Gateway"],"affected":[{"vendor":"Schneider Electric","product":"EcoStruxure IT Gateway","defaultStatus":"unaffected","versions":[{"version":"1.20.x and prior","status":"affected"}]}],"references":["https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-044-03.pdf"],"weaknesses":["CWE-798"],"ingestedAt":"2026-10-29T20:06:42.242Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/0xxx/CVE-2024-0865.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-0865","state":"PUBLISHED","datePublished":"2024-06-12T17:23:00.908Z","dateUpdated":"2024-08-01T18:18:18.824Z","assignerShortName":"schneider","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateReserved":"2024-01-24T17:18:07.117Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"CWE-798: Use of hard-coded credentials vulnerability exists that could cause local privilege\nescalation when logged in as a non-administrative user."}],"affected":[{"vendor":"Schneider Electric","product":"EcoStruxure IT Gateway","defaultStatus":"unaffected","versions":[{"version":"1.20.x and prior","status":"affected"}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-044-03.pdf"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-798","description":"CWE-798 Use of Hard-coded Credentials","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"schneider","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateUpdated":"2024-06-12T17:23:00.908Z"},"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"schneider-electric","product":"ecostruxure_it_gateway","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"1.20.x","versionType":"custom"}],"cpes":["cpe:2.3:a:schneider-electric:ecostruxure_it_gateway:0:*:*:*:*:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-06-12T19:59:08.710375Z","id":"CVE-2024-0865","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-06-12T20:04:39.540Z"}},{"title":"CVE Program Container","references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-044-03.pdf","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-01T18:18:18.824Z"}}]}}}