{"id":"CVE-2024-0220","state":"PUBLISHED","title":"B&R products use insufficient communication encryption","description":"B&R Automation Studio Upgrade Service and B&R Technology Guarding use insufficient cryptography for communication to the upgrade and the licensing servers. A network-based attacker could exploit the vulnerability to execute arbitrary code on the products or sniff sensitive data.","publishedAt":"2024-02-22T10:15:44.750Z","updatedAt":"2024-09-19T17:24:51.723Z","severity":{"score":8.3,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H","source":"ABB"},"assigner":"ABB","products":["B&R Industrial Automation Automation Studio","B&R Industrial Automation Technology Guarding"],"affected":[{"vendor":"B&R Industrial Automation","product":"Automation Studio","defaultStatus":"unaffected","versions":[{"version":"4.0","status":"affected","lessThan":"4.6","versionType":"patch"}],"modules":["Upgrade Service"]},{"vendor":"B&R Industrial Automation","product":"Technology Guarding","defaultStatus":"unaffected","versions":[{"version":"1.0.0","status":"affected","lessThan":"1.4.0","versionType":"patch"}]}],"references":["https://www.br-automation.com/fileadmin/SA23P019_Automation_Studio_Upgrade_Service_uses_insufficient_encryption.pdf-1b3b181c.pdf"],"weaknesses":["CWE-1240","CWE-319","CWE-94"],"ingestedAt":"2026-10-29T20:06:42.242Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2024/0xxx/CVE-2024-0220.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-0220","state":"PUBLISHED","datePublished":"2024-02-22T10:15:44.750Z","dateUpdated":"2024-09-19T17:24:51.723Z","assignerShortName":"ABB","assignerOrgId":"2b718523-d88f-4f37-9bbd-300c20644bf9","dateReserved":"2024-01-03T15:46:41.224Z"},"containers":{"cna":{"title":"B&R products use insufficient communication encryption","descriptions":[{"lang":"en","value":"B&R Automation Studio Upgrade Service and B&R Technology Guarding use insufficient cryptography for communication to the upgrade and the licensing servers. A network-based attacker could exploit the vulnerability to execute arbitrary code on the products or sniff sensitive data."}],"affected":[{"vendor":"B&R Industrial Automation","product":"Automation Studio","defaultStatus":"unaffected","versions":[{"version":"4.0","status":"affected","lessThan":"4.6","versionType":"patch"}],"modules":["Upgrade Service"]},{"vendor":"B&R Industrial Automation","product":"Technology Guarding","defaultStatus":"unaffected","versions":[{"version":"1.0.0","status":"affected","lessThan":"1.4.0","versionType":"patch"}]}],"references":[{"url":"https://www.br-automation.com/fileadmin/SA23P019_Automation_Studio_Upgrade_Service_uses_insufficient_encryption.pdf-1b3b181c.pdf"}],"metrics":[{"cvssV3_1":{"attackComplexity":"HIGH","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8.3,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-1240","description":"CWE-1240: Use of a Cryptographic Primitive with a Risky Implementation","lang":"en","type":"CWE"}]},{"descriptions":[{"cweId":"CWE-319","description":"CWE-319 Cleartext Transmission of Sensitive Information","lang":"en","type":"CWE"}]},{"descriptions":[{"cweId":"CWE-94","description":"CWE-94 Improper Control of Generation of Code ('Code Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"ABB","orgId":"2b718523-d88f-4f37-9bbd-300c20644bf9","dateUpdated":"2024-09-19T17:24:51.723Z"},"datePublic":"2024-02-22T10:10:00.000Z","source":{"advisory":"2023-P019","discovery":"INTERNAL"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://www.br-automation.com/fileadmin/SA23P019_Automation_Studio_Upgrade_Service_uses_insufficient_encryption.pdf-1b3b181c.pdf","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-01T17:41:15.976Z"}},{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"br-automation","product":"automation_studio","defaultStatus":"unknown","versions":[{"version":"4.0","status":"affected","lessThan":"4.6","versionType":"custom"}],"cpes":["cpe:2.3:a:br-automation:automation_studio:*:*:*:*:*:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-02-22T16:23:26.378691Z","id":"CVE-2024-0220","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-08-28T16:52:09.908Z"}}]}}}