{"id":"CVE-2023-5391","state":"PUBLISHED","title":"CVE-2023-5391","description":"\n\n\nA CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker to\nexecute arbitrary code on the targeted system by sending a specifically crafted packet to the\napplication.\n\n\n\n\n","publishedAt":"2023-10-04T18:13:00.746Z","updatedAt":"2025-02-27T20:46:31.823Z","severity":{"score":9.8,"label":"Critical","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","source":"schneider"},"assigner":"schneider","products":["Schneider Electric EcoStruxure Power Monitoring Expert","Schneider Electric EcoStruxure Power Operation (EPO) with Advanced Reports","Schneider Electric EcoStruxure Power SCADA Operation with Advanced Reports"],"affected":[{"vendor":"Schneider Electric","product":"EcoStruxure Power Monitoring Expert","defaultStatus":"unaffected","versions":[{"version":"All versions – prior to application of Hotfix-145271","status":"affected"}]},{"vendor":"Schneider Electric","product":"EcoStruxure Power Operation (EPO) with Advanced Reports","defaultStatus":"unaffected","versions":[{"version":"All versions – prior to application of Hotfix-145271","status":"affected"}]},{"vendor":"Schneider Electric","product":"EcoStruxure Power SCADA Operation with Advanced Reports","defaultStatus":"unaffected","versions":[{"version":"All versions – prior to application of Hotfix-145271","status":"affected"}]}],"references":["https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-283-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-283-02.pdf"],"weaknesses":["CWE-502"],"ingestedAt":"2026-10-29T20:06:42.242Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2023/5xxx/CVE-2023-5391.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-5391","state":"PUBLISHED","datePublished":"2023-10-04T18:13:00.746Z","dateUpdated":"2025-02-27T20:46:31.823Z","assignerShortName":"schneider","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateReserved":"2023-10-04T17:50:08.965Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"\n\n\nA CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker to\nexecute arbitrary code on the targeted system by sending a specifically crafted packet to the\napplication.\n\n\n\n\n"}],"affected":[{"vendor":"Schneider Electric","product":"EcoStruxure Power Monitoring Expert","defaultStatus":"unaffected","versions":[{"version":"All versions – prior to application of Hotfix-145271","status":"affected"}]},{"vendor":"Schneider Electric","product":"EcoStruxure Power Operation (EPO) with Advanced Reports","defaultStatus":"unaffected","versions":[{"version":"All versions – prior to application of Hotfix-145271","status":"affected"}]},{"vendor":"Schneider Electric","product":"EcoStruxure Power SCADA Operation with Advanced Reports","defaultStatus":"unaffected","versions":[{"version":"All versions – prior to application of Hotfix-145271","status":"affected"}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-283-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-283-02.pdf"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-502","description":"CWE-502 Deserialization of Untrusted Data","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"schneider","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateUpdated":"2023-10-11T08:25:11.967Z"},"datePublic":"2023-10-10T17:55:00.000Z","source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-283-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-283-02.pdf","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-02T07:59:44.528Z"}},{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-02-26T21:50:43.582116Z","id":"CVE-2023-5391","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-02-27T20:46:31.823Z"}}]}}}