{"id":"CVE-2023-49722","state":"PUBLISHED","title":"Network port 8899 open in WiFi firmware of BCC101/BCC102/BCC50 products, that allows an attacker to connect to the device via same WiFi network.","description":"Network port 8899 open in WiFi firmware of BCC101/BCC102/BCC50 products, that allows an attacker to connect to the device via same WiFi network.","publishedAt":"2024-01-09T09:54:57.409Z","updatedAt":"2025-06-17T20:39:17.535Z","severity":{"score":8.3,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H","source":"bosch"},"assigner":"bosch","products":["Bosch BCC101","Bosch BCC102","Bosch BCC50"],"affected":[{"vendor":"Bosch","product":"BCC101","versions":[{"version":"4.13.20","status":"affected","lessThan":"v4.13.33","versionType":"custom"}]},{"vendor":"Bosch","product":"BCC102","versions":[{"version":"4.13.20","status":"affected","lessThan":"v4.13.33","versionType":"custom"}]},{"vendor":"Bosch","product":"BCC50","versions":[{"version":"4.13.20","status":"affected","lessThan":"v4.13.33","versionType":"custom"}]}],"references":["https://psirt.bosch.com/security-advisories/BOSCH-SA-473852.html"],"weaknesses":["CWE-1125"],"ingestedAt":"2026-10-29T20:06:24.729Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2023/49xxx/CVE-2023-49722.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-49722","state":"PUBLISHED","datePublished":"2024-01-09T09:54:57.409Z","dateUpdated":"2025-06-17T20:39:17.535Z","assignerShortName":"bosch","assignerOrgId":"c95f66b2-7e7c-41c5-8f09-6f86ec68659c","dateReserved":"2023-11-30T08:50:43.845Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"Network port 8899 open in WiFi firmware of BCC101/BCC102/BCC50 products, that allows an attacker to connect to the device via same WiFi network."}],"affected":[{"vendor":"Bosch","product":"BCC101","versions":[{"version":"4.13.20","status":"affected","lessThan":"v4.13.33","versionType":"custom"}]},{"vendor":"Bosch","product":"BCC102","versions":[{"version":"4.13.20","status":"affected","lessThan":"v4.13.33","versionType":"custom"}]},{"vendor":"Bosch","product":"BCC50","versions":[{"version":"4.13.20","status":"affected","lessThan":"v4.13.33","versionType":"custom"}]}],"references":[{"url":"https://psirt.bosch.com/security-advisories/BOSCH-SA-473852.html","name":"https://psirt.bosch.com/security-advisories/BOSCH-SA-473852.html","tags":["vendor-advisory"]}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":8.3,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-1125","lang":"en-US","description":"CWE-1125 Excessive Attack Surface"}]}],"providerMetadata":{"shortName":"bosch","orgId":"c95f66b2-7e7c-41c5-8f09-6f86ec68659c","dateUpdated":"2024-01-09T09:54:57.409Z"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://psirt.bosch.com/security-advisories/BOSCH-SA-473852.html","name":"https://psirt.bosch.com/security-advisories/BOSCH-SA-473852.html","tags":["vendor-advisory","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-02T22:01:25.866Z"}},{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2023-49722","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"version":"2.0.3","timestamp":"2024-01-09T13:58:04.983004Z"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-06-17T20:39:17.535Z"}}]}}}