{"id":"CVE-2023-48431","state":"PUBLISHED","title":"A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). Affected software does not correctly validate the response received by an UMC server. An attack","description":"A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). Affected software does not correctly validate the response received by an UMC server. An attacker can use this to crash the affected software by providing and configuring a malicious UMC server or by manipulating the traffic from a legitimate UMC server (i.e. leveraging CVE-2023-48427).","publishedAt":"2023-12-12T11:27:23.326Z","updatedAt":"2024-08-02T21:30:35.087Z","severity":{"score":6.8,"label":"Medium","version":"3.1","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C","source":"siemens"},"assigner":"siemens","products":["Siemens SINEC INS"],"affected":[{"vendor":"Siemens","product":"SINEC INS","defaultStatus":"unknown","versions":[{"version":"All versions < V1.0 SP2 Update 2","status":"affected"}]}],"references":["https://cert-portal.siemens.com/productcert/pdf/ssa-077170.pdf"],"weaknesses":["CWE-754"],"ingestedAt":"2026-10-29T20:06:24.729Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2023/48xxx/CVE-2023-48431.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-48431","state":"PUBLISHED","datePublished":"2023-12-12T11:27:23.326Z","dateUpdated":"2024-08-02T21:30:35.087Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2023-11-16T16:30:40.850Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). Affected software does not correctly validate the response received by an UMC server. An attacker can use this to crash the affected software by providing and configuring a malicious UMC server or by manipulating the traffic from a legitimate UMC server (i.e. leveraging CVE-2023-48427)."}],"affected":[{"vendor":"Siemens","product":"SINEC INS","defaultStatus":"unknown","versions":[{"version":"All versions < V1.0 SP2 Update 2","status":"affected"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-077170.pdf"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C","baseScore":6.8,"baseSeverity":"MEDIUM"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-754","lang":"en","description":"CWE-754: Improper Check for Unusual or Exceptional Conditions","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2023-12-12T11:27:23.326Z"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-077170.pdf","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-02T21:30:35.087Z"}}]}}}