{"id":"CVE-2023-4516","state":"PUBLISHED","title":"CVE-2023-4516","description":"\nA CWE-306: Missing Authentication for Critical Function vulnerability exists in the IGSS Update\nService that could allow a local attacker to change update source, potentially leading to remote\ncode execution when the attacker force an update containing malicious content.\n\n","publishedAt":"2023-09-14T08:54:53.673Z","updatedAt":"2025-02-27T20:52:17.879Z","severity":{"score":7.8,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","source":"schneider"},"assigner":"schneider","products":["Schneider Electric IGSS Update Service (IGSSupdateservice.exe)"],"affected":[{"vendor":"Schneider Electric","product":"IGSS Update Service (IGSSupdateservice.exe)","defaultStatus":"unaffected","versions":[{"version":"v16.0.0.23211 and prior","status":"affected"}]}],"references":["https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-255-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-255-01.pdf"],"weaknesses":["CWE-306"],"ingestedAt":"2026-10-29T20:06:33.064Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2023/4xxx/CVE-2023-4516.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-4516","state":"PUBLISHED","datePublished":"2023-09-14T08:54:53.673Z","dateUpdated":"2025-02-27T20:52:17.879Z","assignerShortName":"schneider","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateReserved":"2023-08-24T10:47:22.919Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"\nA CWE-306: Missing Authentication for Critical Function vulnerability exists in the IGSS Update\nService that could allow a local attacker to change update source, potentially leading to remote\ncode execution when the attacker force an update containing malicious content.\n\n"}],"affected":[{"vendor":"Schneider Electric","product":"IGSS Update Service (IGSSupdateservice.exe)","defaultStatus":"unaffected","versions":[{"version":"v16.0.0.23211 and prior","status":"affected"}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-255-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-255-01.pdf"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-306","description":"CWE-306 Missing Authentication for Critical Function","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"schneider","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateUpdated":"2023-09-14T08:54:53.673Z"},"datePublic":"2023-09-12T08:53:00.000Z","source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-255-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-255-01.pdf","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-02T07:31:06.157Z"}},{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-02-26T21:51:14.783705Z","id":"CVE-2023-4516","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-02-27T20:52:17.879Z"}}]}}}