{"id":"CVE-2023-41372","state":"PUBLISHED","title":"The vulnerability allows an unprivileged (untrusted) third- party application to arbitrary modify the server settings of the Android Client application, inducing it to connect to a","description":"The vulnerability allows an unprivileged (untrusted) third- party application to arbitrary modify the server settings of the Android Client application, inducing it to connect to an attacker - controlled malicious server.This is possible by forging a valid broadcast intent encrypted with a hardcoded RSA key pair","publishedAt":"2023-10-25T14:13:34.827Z","updatedAt":"2024-09-12T14:28:34.281Z","severity":{"score":7.8,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","source":"bosch"},"assigner":"bosch","products":["Rexroth ctrlX HMI Web Panel - WR21 (WR2107)","Rexroth ctrlX HMI Web Panel - WR21 (WR2110)","Rexroth ctrlX HMI Web Panel - WR21 (WR2115)"],"affected":[{"vendor":"Rexroth","product":"ctrlX HMI Web Panel - WR21 (WR2107)","versions":[{"version":"all","status":"affected"}]},{"vendor":"Rexroth","product":"ctrlX HMI Web Panel - WR21 (WR2110)","versions":[{"version":"all","status":"affected"}]},{"vendor":"Rexroth","product":"ctrlX HMI Web Panel - WR21 (WR2115)","versions":[{"version":"all","status":"affected"}]}],"references":["https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"],"weaknesses":["CWE-798"],"ingestedAt":"2026-10-29T20:06:17.512Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2023/41xxx/CVE-2023-41372.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-41372","state":"PUBLISHED","datePublished":"2023-10-25T14:13:34.827Z","dateUpdated":"2024-09-12T14:28:34.281Z","assignerShortName":"bosch","assignerOrgId":"c95f66b2-7e7c-41c5-8f09-6f86ec68659c","dateReserved":"2023-10-18T09:35:22.507Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"The vulnerability allows an unprivileged (untrusted) third- party application to arbitrary modify the server settings of the Android Client application, inducing it to connect to an attacker - controlled malicious server.This is possible by forging a valid broadcast intent encrypted with a hardcoded RSA key pair"}],"affected":[{"vendor":"Rexroth","product":"ctrlX HMI Web Panel - WR21 (WR2107)","versions":[{"version":"all","status":"affected"}]},{"vendor":"Rexroth","product":"ctrlX HMI Web Panel - WR21 (WR2110)","versions":[{"version":"all","status":"affected"}]},{"vendor":"Rexroth","product":"ctrlX HMI Web Panel - WR21 (WR2115)","versions":[{"version":"all","status":"affected"}]}],"references":[{"url":"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html","name":"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html","tags":["vendor-advisory"]}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-798","lang":"en-US","description":"CWE-798 Use of Hard-coded Credentials"}]}],"providerMetadata":{"shortName":"bosch","orgId":"c95f66b2-7e7c-41c5-8f09-6f86ec68659c","dateUpdated":"2023-10-25T14:13:34.827Z"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html","name":"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html","tags":["vendor-advisory","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-02T19:01:35.280Z"}},{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"boschrexroth","product":"ctrlx_hmi_web_panel_wr2107","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}],"cpes":["cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*"]},{"vendor":"boschrexroth","product":"ctrlx_hmi_web_panel_wr2110","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}],"cpes":["cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*"]},{"vendor":"boschrexroth","product":"ctrlx_hmi_web_panel_wr2115","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}],"cpes":["cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-09-10T18:51:52.995688Z","id":"CVE-2023-41372","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-09-12T14:28:34.281Z"}}]}}}