{"id":"CVE-2023-38679","state":"PUBLISHED","title":"A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected ap","description":"A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21106)","publishedAt":"2023-08-08T09:20:44.162Z","updatedAt":"2024-10-11T13:51:47.510Z","severity":{"score":7.8,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","source":"siemens"},"assigner":"siemens","products":["Siemens Tecnomatix Plant Simulation V2201","Siemens Tecnomatix Plant Simulation V2302"],"affected":[{"vendor":"Siemens","product":"Tecnomatix Plant Simulation V2201","defaultStatus":"unknown","versions":[{"version":"All versions < V2201.0008","status":"affected"}]},{"vendor":"Siemens","product":"Tecnomatix Plant Simulation V2302","defaultStatus":"unknown","versions":[{"version":"All versions < V2302.0002","status":"affected"}]}],"references":["https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf"],"weaknesses":["CWE-787"],"ingestedAt":"2026-10-29T20:06:08.715Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2023/38xxx/CVE-2023-38679.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-38679","state":"PUBLISHED","datePublished":"2023-08-08T09:20:44.162Z","dateUpdated":"2024-10-11T13:51:47.510Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2023-07-24T09:52:57.445Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21106)"}],"affected":[{"vendor":"Siemens","product":"Tecnomatix Plant Simulation V2201","defaultStatus":"unknown","versions":[{"version":"All versions < V2201.0008","status":"affected"}]},{"vendor":"Siemens","product":"Tecnomatix Plant Simulation V2302","defaultStatus":"unknown","versions":[{"version":"All versions < V2302.0002","status":"affected"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","baseScore":7.8,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-787","lang":"en","description":"CWE-787: Out-of-bounds Write","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2023-09-12T09:32:21.363Z"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-02T17:46:56.831Z"}},{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-10-11T13:51:35.961319Z","id":"CVE-2023-38679","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-10-11T13:51:47.510Z"}}]}}}