{"id":"CVE-2023-37557","state":"PUBLISHED","title":"CODESYS Heap-based Buffer Overflow in multiple products","description":"After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition.","publishedAt":"2023-08-03T11:06:17.884Z","updatedAt":"2024-10-09T20:52:16.817Z","severity":{"score":6.5,"label":"Medium","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","source":"CERTVDE"},"assigner":"CERTVDE","products":["CODESYS CODESYS Control for BeagleBone SL","CODESYS CODESYS Control for emPC-A/iMX6 SL","CODESYS CODESYS Control for IOT2000 SL","CODESYS CODESYS Control for Linux SL","CODESYS CODESYS Control for PFC100 SL","CODESYS CODESYS Control for PFC200 SL","CODESYS CODESYS Control for PLCnext SL","CODESYS CODESYS Control for Raspberry Pi SL","CODESYS CODESYS Control for WAGO Touch Panels 600 SL","CODESYS CODESYS Control RTE (for Beckhoff CX) SL","CODESYS CODESYS Control RTE (SL)","CODESYS CODESYS Control Runtime System Toolkit","CODESYS CODESYS Control Win (SL)","CODESYS CODESYS Development System V3","CODESYS CODESYS HMI (SL)","CODESYS CODESYS Safety SIL2 Runtime Toolkit"],"affected":[{"vendor":"CODESYS","product":"CODESYS Control for BeagleBone SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V4.10.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for emPC-A/iMX6 SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V4.10.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for IOT2000 SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V4.10.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for Linux SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V4.10.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for PFC100 SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V4.10.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for PFC200 SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V4.10.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for PLCnext SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V4.10.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for Raspberry Pi SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V4.10.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for WAGO Touch Panels 600 SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V4.10.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control RTE (for Beckhoff CX) SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V3.5.19.20","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control RTE (SL)","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V3.5.19.20","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control Runtime System Toolkit","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V3.5.19.20","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control Win (SL)","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V3.5.19.20","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Development System V3","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V3.5.19.20","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS HMI (SL)","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V3.5.19.20","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Safety SIL2 Runtime Toolkit","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V3.5.19.20","versionType":"semver"}]}],"references":["https://cert.vde.com/en/advisories/VDE-2023-019/"],"weaknesses":["CWE-787"],"ingestedAt":"2026-10-29T20:06:08.715Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2023/37xxx/CVE-2023-37557.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-37557","state":"PUBLISHED","datePublished":"2023-08-03T11:06:17.884Z","dateUpdated":"2024-10-09T20:52:16.817Z","assignerShortName":"CERTVDE","assignerOrgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","dateReserved":"2023-07-07T07:39:19.121Z"},"containers":{"cna":{"title":"CODESYS Heap-based Buffer Overflow in multiple products","descriptions":[{"lang":"en","value":"After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition."}],"affected":[{"vendor":"CODESYS","product":"CODESYS Control for BeagleBone SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V4.10.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for emPC-A/iMX6 SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V4.10.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for IOT2000 SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V4.10.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for Linux SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V4.10.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for PFC100 SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V4.10.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for PFC200 SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V4.10.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for PLCnext SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V4.10.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for Raspberry Pi SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V4.10.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for WAGO Touch Panels 600 SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V4.10.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control RTE (for Beckhoff CX) SL","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V3.5.19.20","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control RTE (SL)","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V3.5.19.20","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control Runtime System Toolkit","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V3.5.19.20","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control Win (SL)","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V3.5.19.20","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Development System V3","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V3.5.19.20","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS HMI (SL)","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V3.5.19.20","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Safety SIL2 Runtime Toolkit","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"V3.5.19.20","versionType":"semver"}]}],"references":[{"url":"https://cert.vde.com/en/advisories/VDE-2023-019/"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":6.5,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-787","description":"CWE-787 Out-of-bounds Write","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"CERTVDE","orgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","dateUpdated":"2023-08-03T11:06:17.884Z"},"credits":[{"lang":"en","type":"finder","user":"00000000-0000-4000-9000-000000000000","value":"Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"}],"datePublic":"2023-08-03T10:30:00.000Z","source":{"advisory":"VDE-2023-019","defect":["CERT@VDE#64558"],"discovery":"EXTERNAL"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://cert.vde.com/en/advisories/VDE-2023-019/","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-02T17:16:30.379Z"}},{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-10-09T20:48:56.664856Z","id":"CVE-2023-37557","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-10-09T20:52:16.817Z"}}]}}}