{"id":"CVE-2023-35796","state":"PUBLISHED","title":"A vulnerability has been identified in SINEMA Server V14 (All versions). The affected application improperly sanitizes certain SNMP configuration data retrieved from monitored devi","description":"A vulnerability has been identified in SINEMA Server V14 (All versions). The affected application improperly sanitizes certain SNMP configuration data retrieved from monitored devices. An attacker with access to a monitored device could perform a stored cross-site scripting (XSS) attack that may lead to arbitrary code execution with `SYSTEM` privileges on the application server. (ZDI-CAN-19823)","publishedAt":"2023-10-10T10:21:20.721Z","updatedAt":"2024-09-19T14:28:45.193Z","severity":{"score":8.3,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H/E:P/RL:U/RC:C","source":"siemens"},"assigner":"siemens","products":["Siemens SINEMA Server V14"],"affected":[{"vendor":"Siemens","product":"SINEMA Server V14","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]}],"references":["https://cert-portal.siemens.com/productcert/pdf/ssa-594373.pdf"],"weaknesses":["CWE-79"],"ingestedAt":"2026-10-29T20:06:00.499Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2023/35xxx/CVE-2023-35796.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-35796","state":"PUBLISHED","datePublished":"2023-10-10T10:21:20.721Z","dateUpdated":"2024-09-19T14:28:45.193Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2023-06-17T10:50:05.752Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SINEMA Server V14 (All versions). The affected application improperly sanitizes certain SNMP configuration data retrieved from monitored devices. An attacker with access to a monitored device could perform a stored cross-site scripting (XSS) attack that may lead to arbitrary code execution with `SYSTEM` privileges on the application server. (ZDI-CAN-19823)"}],"affected":[{"vendor":"Siemens","product":"SINEMA Server V14","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-594373.pdf"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H/E:P/RL:U/RC:C","baseScore":8.3,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-79","lang":"en","description":"CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2023-10-10T10:21:20.721Z"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-594373.pdf","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-02T16:30:45.366Z"}},{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-09-19T14:28:23.445062Z","id":"CVE-2023-35796","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-09-19T14:28:45.193Z"}}]}}}