{"id":"CVE-2023-33919","state":"PUBLISHED","title":"A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05), CP-8050 MASTER MODULE (All versions < CPCI85 V05). The web interface of affected devices i","description":"A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05), CP-8050 MASTER MODULE (All versions < CPCI85 V05). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.","publishedAt":"2023-06-13T08:17:18.755Z","updatedAt":"2025-11-03T20:35:33.949Z","severity":{"score":7.2,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","source":"siemens"},"assigner":"siemens","products":["Siemens CP-8031 MASTER MODULE","Siemens CP-8050 MASTER MODULE"],"affected":[{"vendor":"Siemens","product":"CP-8031 MASTER MODULE","defaultStatus":"unknown","versions":[{"version":"All versions < CPCI85 V05","status":"affected"}]},{"vendor":"Siemens","product":"CP-8050 MASTER MODULE","defaultStatus":"unknown","versions":[{"version":"All versions < CPCI85 V05","status":"affected"}]}],"references":["https://cert-portal.siemens.com/productcert/pdf/ssa-731916.pdf","http://seclists.org/fulldisclosure/2023/Jul/14","http://packetstormsecurity.com/files/173370/Siemens-A8000-CP-8050-CP-8031-Code-Execution-Command-Injection.html","http://seclists.org/fulldisclosure/2024/Jul/4","http://seclists.org/fulldisclosure/2025/Feb/19"],"weaknesses":["CWE-77"],"ingestedAt":"2026-10-29T20:06:00.499Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2023/33xxx/CVE-2023-33919.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2023-33919","state":"PUBLISHED","datePublished":"2023-06-13T08:17:18.755Z","dateUpdated":"2025-11-03T20:35:33.949Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2023-05-23T10:09:31.037Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05), CP-8050 MASTER MODULE (All versions < CPCI85 V05). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges."}],"affected":[{"vendor":"Siemens","product":"CP-8031 MASTER MODULE","defaultStatus":"unknown","versions":[{"version":"All versions < CPCI85 V05","status":"affected"}]},{"vendor":"Siemens","product":"CP-8050 MASTER MODULE","defaultStatus":"unknown","versions":[{"version":"All versions < CPCI85 V05","status":"affected"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-731916.pdf"},{"url":"http://seclists.org/fulldisclosure/2023/Jul/14"},{"url":"http://packetstormsecurity.com/files/173370/Siemens-A8000-CP-8050-CP-8031-Code-Execution-Command-Injection.html"},{"url":"http://seclists.org/fulldisclosure/2024/Jul/4"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","baseScore":7.2,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-77","lang":"en","description":"CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection')","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2024-07-04T06:06:07.699Z"}},"adp":[{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"siemens","product":"cp-8031_master_module","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"CVE-2022-33307","versionType":"custom"}],"cpes":["cpe:2.3:h:siemens:cp-8031_master_module:-:*:*:*:*:*:*:*"]},{"vendor":"siemens","product":"cp-8050_master_module","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"CVE-2022-33307","versionType":"custom"}],"cpes":["cpe:2.3:h:siemens:cp-8050_master_module:-:*:*:*:*:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-07-05T20:17:08.721536Z","id":"CVE-2023-33919","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-07-06T14:12:00.475Z"}},{"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-731916.pdf","tags":["x_transferred"]},{"url":"http://seclists.org/fulldisclosure/2023/Jul/14","tags":["x_transferred"]},{"url":"http://packetstormsecurity.com/files/173370/Siemens-A8000-CP-8050-CP-8031-Code-Execution-Command-Injection.html","tags":["x_transferred"]},{"url":"http://seclists.org/fulldisclosure/2024/Jul/4","tags":["x_transferred"]},{"url":"http://seclists.org/fulldisclosure/2025/Feb/19"}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2025-11-03T20:35:33.949Z"}}]}}}