{"id":"CVE-2023-33217","state":"PUBLISHED","title":"Missing integrity check on upgrade package","description":"\nBy abusing a design flaw in the firmware upgrade mechanism of the impacted terminal it's possible to cause a permanent \ndenial of service for the terminal. the only way to recover the terminal is by sending back the terminal to the manufacturer","publishedAt":"2023-12-15T10:45:30.637Z","updatedAt":"2024-08-02T15:39:35.734Z","severity":{"score":7.5,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","source":"IDEMIA"},"assigner":"IDEMIA","products":["IDEMIA SIGMA Lite & Lite +","IDEMIA SIGMA Wide","IDEMIA SIGMA Extreme","IDEMIA MorphoWave Compact/XP","IDEMIA VisionPass","IDEMIA MorphoWave SP"],"affected":[{"vendor":"IDEMIA","product":"SIGMA Lite & Lite +","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"4.15.5","versionType":"custom"}]},{"vendor":"IDEMIA","product":"SIGMA Wide","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"4.15.5","versionType":"custom"}]},{"vendor":"IDEMIA","product":"SIGMA Extreme","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"4.15.5","versionType":"custom"}]},{"vendor":"IDEMIA","product":"MorphoWave Compact/XP","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"2.12.2","versionType":"custom"}]},{"vendor":"IDEMIA","product":"VisionPass","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"2.12.2","versionType":"custom"}]},{"vendor":"IDEMIA","product":"MorphoWave SP","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"1.2.7","versionType":"custom"}]}],"references":["https://www.idemia.com/wp-content/uploads/2023/11/Security-Advisory-SA-2023-05-2.pdf"],"weaknesses":["CWE-20"],"ingestedAt":"2026-10-29T20:06:00.499Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2023/33xxx/CVE-2023-33217.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-33217","state":"PUBLISHED","datePublished":"2023-12-15T10:45:30.637Z","dateUpdated":"2024-08-02T15:39:35.734Z","assignerShortName":"IDEMIA","assignerOrgId":"a87f365f-9d39-4848-9b3a-58c7cae69cab","dateReserved":"2023-05-18T14:32:49.222Z"},"containers":{"cna":{"title":"Missing integrity check on upgrade package","descriptions":[{"lang":"en","value":"\nBy abusing a design flaw in the firmware upgrade mechanism of the impacted terminal it's possible to cause a permanent \ndenial of service for the terminal. the only way to recover the terminal is by sending back the terminal to the manufacturer"}],"affected":[{"vendor":"IDEMIA","product":"SIGMA Lite & Lite +","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"4.15.5","versionType":"custom"}]},{"vendor":"IDEMIA","product":"SIGMA Wide","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"4.15.5","versionType":"custom"}]},{"vendor":"IDEMIA","product":"SIGMA Extreme","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"4.15.5","versionType":"custom"}]},{"vendor":"IDEMIA","product":"MorphoWave Compact/XP","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"2.12.2","versionType":"custom"}]},{"vendor":"IDEMIA","product":"VisionPass","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"2.12.2","versionType":"custom"}]},{"vendor":"IDEMIA","product":"MorphoWave SP","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"1.2.7","versionType":"custom"}]}],"references":[{"url":"https://www.idemia.com/wp-content/uploads/2023/11/Security-Advisory-SA-2023-05-2.pdf"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]},{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":4.9,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"if you have kept the default Enforced Security mode or enabled the mTLS to identify the origin of the  command issued to the termina"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-20","description":"CWE-20 Improper Input Validation","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"IDEMIA","orgId":"a87f365f-9d39-4848-9b3a-58c7cae69cab","dateUpdated":"2023-12-15T10:45:30.637Z"},"impacts":[{"capecId":"CAPEC-153","descriptions":[{"lang":"en","value":"CAPEC-153 Input Data Manipulation"}]}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://www.idemia.com/wp-content/uploads/2023/11/Security-Advisory-SA-2023-05-2.pdf","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-02T15:39:35.734Z"}}]}}}