{"id":"CVE-2023-32469","state":"PUBLISHED","title":"CVE-2023-32469","description":"\nDell Precision Tower BIOS contains an Improper Input Validation vulnerability. A locally authenticated malicious user with admin privileges could potentially exploit this vulnerability to perform arbitrary code execution.\n\n","publishedAt":"2023-11-16T08:14:46.815Z","updatedAt":"2024-08-02T15:18:37.134Z","severity":{"score":7.5,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H","source":"dell"},"assigner":"dell","products":["Dell Dell Precision 5820 Tower, Dell Precision 7820 Tower, Dell Precision 7920 Tower"],"affected":[{"vendor":"Dell","product":"Dell Precision 5820 Tower, Dell Precision 7820 Tower, Dell Precision 7920 Tower","defaultStatus":"unaffected","versions":[{"version":"Versions prior to 2.32.0","status":"affected"},{"version":"Versions prior to 2.36.0","status":"affected"}],"platforms":["BIOS"]}],"references":["https://www.dell.com/support/kbdoc/en-us/000216242/dsa-2023-223-security-update-for-a-dell-precision-tower-bios-vulnerability"],"weaknesses":["CWE-20"],"ingestedAt":"2026-10-29T20:06:00.499Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2023/32xxx/CVE-2023-32469.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-32469","state":"PUBLISHED","datePublished":"2023-11-16T08:14:46.815Z","dateUpdated":"2024-08-02T15:18:37.134Z","assignerShortName":"dell","assignerOrgId":"c550e75a-17ff-4988-97f0-544cde3820fe","dateReserved":"2023-05-09T06:07:41.364Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"\nDell Precision Tower BIOS contains an Improper Input Validation vulnerability. A locally authenticated malicious user with admin privileges could potentially exploit this vulnerability to perform arbitrary code execution.\n\n"}],"affected":[{"vendor":"Dell","product":"Dell Precision 5820 Tower, Dell Precision 7820 Tower, Dell Precision 7920 Tower","defaultStatus":"unaffected","versions":[{"version":"Versions prior to 2.32.0","status":"affected"},{"version":"Versions prior to 2.36.0","status":"affected"}],"platforms":["BIOS"]}],"references":[{"url":"https://www.dell.com/support/kbdoc/en-us/000216242/dsa-2023-223-security-update-for-a-dell-precision-tower-bios-vulnerability","tags":["vendor-advisory"]}],"metrics":[{"cvssV3_1":{"attackComplexity":"HIGH","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"HIGH","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-20","description":"CWE-20: Improper Input Validation","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"dell","orgId":"c550e75a-17ff-4988-97f0-544cde3820fe","dateUpdated":"2023-11-16T08:14:46.815Z"},"credits":[{"lang":"en","type":"finder","user":"00000000-0000-4000-9000-000000000000","value":"another1024"}],"datePublic":"2023-11-14T06:30:00.000Z","source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://www.dell.com/support/kbdoc/en-us/000216242/dsa-2023-223-security-update-for-a-dell-precision-tower-bios-vulnerability","tags":["vendor-advisory","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-02T15:18:37.134Z"}}]}}}