{"id":"CVE-2023-29414","state":"PUBLISHED","title":"CVE-2023-29414","description":"\nA CWE-120: Buffer Copy without Checking Size of Input (Classic Buffer Overflow) vulnerability\nexists that could cause user privilege escalation if a local user sends specific string input to a\nlocal function call.\n\n","publishedAt":"2023-07-12T08:18:01.709Z","updatedAt":"2024-11-07T14:44:09.486Z","severity":{"score":7.8,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","source":"schneider"},"assigner":"schneider","products":["Schneider Electric Accutech Manager"],"affected":[{"vendor":"Schneider Electric","product":"Accutech Manager","defaultStatus":"unaffected","versions":[{"version":"Version 2.7 and prior","status":"affected"}]}],"references":["https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-03.pdf"],"weaknesses":["CWE-120"],"ingestedAt":"2026-10-29T20:05:52.290Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2023/29xxx/CVE-2023-29414.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-29414","state":"PUBLISHED","datePublished":"2023-07-12T08:18:01.709Z","dateUpdated":"2024-11-07T14:44:09.486Z","assignerShortName":"schneider","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateReserved":"2023-04-05T20:35:41.368Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"\nA CWE-120: Buffer Copy without Checking Size of Input (Classic Buffer Overflow) vulnerability\nexists that could cause user privilege escalation if a local user sends specific string input to a\nlocal function call.\n\n"}],"affected":[{"vendor":"Schneider Electric","product":"Accutech Manager","defaultStatus":"unaffected","versions":[{"version":"Version 2.7 and prior","status":"affected"}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-03.pdf"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-120","description":"CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"schneider","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateUpdated":"2023-07-12T08:18:01.709Z"},"datePublic":"2023-07-11T08:17:00.000Z","source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-03.pdf","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-02T14:07:45.730Z"}},{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"schneider-electric","product":"accutech_manager","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThanOrEqual":"2.7","versionType":"custom"}],"cpes":["cpe:2.3:a:schneider-electric:accutech_manager:*:*:*:*:*:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-11-07T14:42:01.511585Z","id":"CVE-2023-29414","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-11-07T14:44:09.486Z"}}]}}}