{"id":"CVE-2023-2880","state":"PUBLISHED","title":"Frauscher Sensortechnik Diagnostic System FDS001 for FAdC/FAdCi Path Traversal vulnerability","description":"Frauscher Sensortechnik GmbH FDS001 for FAdC/FAdCi v1.3.3 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS001 device.","publishedAt":"2023-07-05T09:04:28.091Z","updatedAt":"2024-11-20T21:26:10.093Z","severity":{"score":7.5,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","source":"CERTVDE"},"assigner":"CERTVDE","products":["Frauscher Sensortechnik Diagnostic System FDS101 for FAdC/FAdCi"],"affected":[{"vendor":"Frauscher Sensortechnik","product":"Diagnostic System FDS101 for FAdC/FAdCi","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"1.3.3","versionType":"semver"}]}],"references":["https://cert.vde.com/en/advisories/VDE-2023-011/"],"weaknesses":["CWE-22"],"ingestedAt":"2026-10-29T20:05:52.290Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2023/2xxx/CVE-2023-2880.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-2880","state":"PUBLISHED","datePublished":"2023-07-05T09:04:28.091Z","dateUpdated":"2024-11-20T21:26:10.093Z","assignerShortName":"CERTVDE","assignerOrgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","dateReserved":"2023-05-25T07:17:13.633Z"},"containers":{"cna":{"title":"Frauscher Sensortechnik Diagnostic System FDS001 for FAdC/FAdCi Path Traversal vulnerability","descriptions":[{"lang":"en","value":"Frauscher Sensortechnik GmbH FDS001 for FAdC/FAdCi v1.3.3 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS001 device."}],"affected":[{"vendor":"Frauscher Sensortechnik","product":"Diagnostic System FDS101 for FAdC/FAdCi","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"1.3.3","versionType":"semver"}]}],"references":[{"url":"https://cert.vde.com/en/advisories/VDE-2023-011/"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-22","description":"CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"CERTVDE","orgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","dateUpdated":"2023-07-05T09:04:28.091Z"},"source":{"advisory":"VDE-2023-011","defect":["CERT@VDE#64526"],"discovery":"INTERNAL"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://cert.vde.com/en/advisories/VDE-2023-011/","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-02T06:41:02.358Z"}},{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-11-20T21:26:00.294473Z","id":"CVE-2023-2880","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-11-20T21:26:10.093Z"}}]}}}