{"id":"CVE-2023-28003","state":"PUBLISHED","title":"CVE-2023-28003","description":"\n\n\nA CWE-613: Insufficient Session Expiration vulnerability exists that could allow an attacker to\nmaintain unauthorized access over a hijacked session in PME after the legitimate user has\nsigned out of their account.\n\n\n\n","publishedAt":"2023-04-18T20:43:50.362Z","updatedAt":"2025-02-05T21:23:55.818Z","severity":{"score":6.7,"label":"Medium","version":"3.1","vector":"CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H","source":"schneider"},"assigner":"schneider","products":["Schneider Electric EcoStruxure Power Monitoring Expert"],"affected":[{"vendor":"Schneider Electric","product":"EcoStruxure Power Monitoring Expert","defaultStatus":"unaffected","versions":[{"version":"All ","status":"affected","lessThanOrEqual":"PME 2022","versionType":"custom"}]}],"references":["https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-073-01.pdf"],"weaknesses":["CWE-613"],"ingestedAt":"2026-10-29T20:05:52.290Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2023/28xxx/CVE-2023-28003.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-28003","state":"PUBLISHED","datePublished":"2023-04-18T20:43:50.362Z","dateUpdated":"2025-02-05T21:23:55.818Z","assignerShortName":"schneider","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateReserved":"2023-03-09T15:40:32.544Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"\n\n\nA CWE-613: Insufficient Session Expiration vulnerability exists that could allow an attacker to\nmaintain unauthorized access over a hijacked session in PME after the legitimate user has\nsigned out of their account.\n\n\n\n"}],"affected":[{"vendor":"Schneider Electric","product":"EcoStruxure Power Monitoring Expert","defaultStatus":"unaffected","versions":[{"version":"All ","status":"affected","lessThanOrEqual":"PME 2022","versionType":"custom"}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-073-01.pdf"}],"metrics":[{"cvssV3_1":{"attackComplexity":"HIGH","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":6.7,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-613","description":"CWE-613 Insufficient Session Expiration","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"schneider","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateUpdated":"2023-04-18T20:43:50.362Z"},"datePublic":"2023-03-14T07:00:00.000Z","source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-073-01.pdf","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-02T12:23:30.805Z"}},{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-02-05T21:23:43.454658Z","id":"CVE-2023-28003","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-02-05T21:23:55.818Z"}}]}}}