{"id":"CVE-2023-27984","state":"PUBLISHED","title":"A CWE-20: Improper Input Validation vulnerability exists in Custom Reports that could cause a macro to be executed, potentially leading to remote code execution when a user opens a","description":"A CWE-20: Improper Input Validation vulnerability exists in Custom Reports that could cause a macro to be executed, potentially leading to remote code execution when a user opens a malicious report file planted by an attacker. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).","publishedAt":"2023-03-21T00:00:00.000Z","updatedAt":"2025-02-05T20:05:14.263Z","severity":{"score":7.8,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","source":"schneider"},"assigner":"schneider","products":["Schneider Electric IGSS Data Server(IGSSdataServer.exe)","Schneider Electric IGSS Dashboard (DashBoard.exe)","Schneider Electric Custom Reports (RMS16.dll)"],"affected":[{"vendor":"Schneider Electric","product":"IGSS Data Server(IGSSdataServer.exe)","versions":[{"version":"V","status":"affected","lessThanOrEqual":"16.0.0.23040","versionType":"custom"}]},{"vendor":"Schneider Electric","product":"IGSS Dashboard (DashBoard.exe)","versions":[{"version":"V","status":"affected","lessThanOrEqual":"16.0.0.23040","versionType":"custom"}]},{"vendor":"Schneider Electric","product":"Custom Reports (RMS16.dll)","versions":[{"version":"V","status":"affected","lessThanOrEqual":"16.0.0.23040","versionType":"custom"}]}],"references":["https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-073-04.pdf"],"weaknesses":["CWE-20"],"ingestedAt":"2026-10-29T20:05:52.290Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2023/27xxx/CVE-2023-27984.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-27984","state":"PUBLISHED","datePublished":"2023-03-21T00:00:00.000Z","dateUpdated":"2025-02-05T20:05:14.263Z","assignerShortName":"schneider","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateReserved":"2023-03-09T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A CWE-20: Improper Input Validation vulnerability exists in Custom Reports that could cause a macro to be executed, potentially leading to remote code execution when a user opens a malicious report file planted by an attacker. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior)."}],"affected":[{"vendor":"Schneider Electric","product":"IGSS Data Server(IGSSdataServer.exe)","versions":[{"version":"V","status":"affected","lessThanOrEqual":"16.0.0.23040","versionType":"custom"}]},{"vendor":"Schneider Electric","product":"IGSS Dashboard (DashBoard.exe)","versions":[{"version":"V","status":"affected","lessThanOrEqual":"16.0.0.23040","versionType":"custom"}]},{"vendor":"Schneider Electric","product":"Custom Reports (RMS16.dll)","versions":[{"version":"V","status":"affected","lessThanOrEqual":"16.0.0.23040","versionType":"custom"}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-073-04.pdf"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-20","type":"CWE","lang":"en","description":"CWE-20 Improper Input Validation"}]}],"providerMetadata":{"shortName":"schneider","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateUpdated":"2023-03-21T00:00:00.000Z"},"x_generator":{"engine":"Vulnogram 0.0.9"},"source":{"discovery":"UNKNOWN"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-073-04.pdf","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-02T12:23:30.848Z"}},{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-02-05T19:51:46.135370Z","id":"CVE-2023-27984","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-02-05T20:05:14.263Z"}}]}}}