{"id":"CVE-2023-23691","state":"PUBLISHED","title":"CVE-2023-23691","description":"\nDell EMC PV ME5, versions ME5.1.0.0.0 and ME5.1.0.1.0, contains a Client-side desync Vulnerability. An unauthenticated attacker could potentially exploit this vulnerability to force a victim's browser to desynchronize its connection with the website, typically leading to XSS and DoS.\n\n","publishedAt":"2023-01-20T07:16:02.818Z","updatedAt":"2025-04-02T13:38:18.171Z","severity":{"score":8.1,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","source":"dell"},"assigner":"dell","products":["Dell Dell PowerVault ME5"],"affected":[{"vendor":"Dell","product":"Dell PowerVault ME5","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"ME5.1.1.0.5","versionType":"custom"}]}],"references":["https://www.dell.com/support/kbdoc/en-us/000207533/dsa-2023-018-dell-emc-powervault-me5-security-update-for-a-client-desync-attack-vulnerability"],"weaknesses":["CWE-444"],"ingestedAt":"2026-10-29T20:05:43.909Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2023/23xxx/CVE-2023-23691.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-23691","state":"PUBLISHED","datePublished":"2023-01-20T07:16:02.818Z","dateUpdated":"2025-04-02T13:38:18.171Z","assignerShortName":"dell","assignerOrgId":"c550e75a-17ff-4988-97f0-544cde3820fe","dateReserved":"2023-01-17T05:22:17.394Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"\nDell EMC PV ME5, versions ME5.1.0.0.0 and ME5.1.0.1.0, contains a Client-side desync Vulnerability. An unauthenticated attacker could potentially exploit this vulnerability to force a victim's browser to desynchronize its connection with the website, typically leading to XSS and DoS.\n\n"}],"affected":[{"vendor":"Dell","product":"Dell PowerVault ME5","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"ME5.1.1.0.5","versionType":"custom"}]}],"references":[{"url":"https://www.dell.com/support/kbdoc/en-us/000207533/dsa-2023-018-dell-emc-powervault-me5-security-update-for-a-client-desync-attack-vulnerability","tags":["vendor-advisory"]}],"metrics":[{"cvssV3_1":{"attackComplexity":"HIGH","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8.1,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-444","description":"CWE-444: Inconsistent Interpretation of HTTP Requests ('HTTP Request Smuggling')","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"dell","orgId":"c550e75a-17ff-4988-97f0-544cde3820fe","dateUpdated":"2023-01-20T07:16:02.818Z"},"datePublic":"2023-01-17T06:30:00.000Z","source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://www.dell.com/support/kbdoc/en-us/000207533/dsa-2023-018-dell-emc-powervault-me5-security-update-for-a-client-desync-attack-vulnerability","tags":["vendor-advisory","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-02T10:35:33.687Z"}},{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-04-02T13:37:54.635766Z","id":"CVE-2023-23691","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-04-02T13:38:18.171Z"}}]}}}