{"id":"CVE-2023-22932","state":"PUBLISHED","title":"Persistent Cross-Site Scripting through a Base64-encoded Image in a View in Splunk Enterprise","description":"In Splunk Enterprise 9.0 versions before 9.0.4, a View allows for Cross-Site Scripting (XSS) through the error message in a Base64-encoded image. The vulnerability affects instances with Splunk Web enabled. It does not affect Splunk Enterprise versions below 9.0.","publishedAt":"2023-02-14T17:22:38.739Z","updatedAt":"2025-02-28T11:03:57.639Z","severity":{"score":8,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:N","source":"Splunk"},"assigner":"Splunk","products":["Splunk Splunk Enterprise","Splunk Splunk Cloud Platform"],"affected":[{"vendor":"Splunk","product":"Splunk Enterprise","versions":[{"version":"9.0","status":"affected","lessThan":"9.0.4","versionType":"custom"}]},{"vendor":"Splunk","product":"Splunk Cloud Platform","versions":[{"version":"-","status":"affected","lessThan":"9.0.2209.3","versionType":"custom"}]}],"references":["https://advisory.splunk.com/advisories/SVD-2023-0202","https://research.splunk.com/application/ce6e1268-e01c-4df2-a617-0f034ed49a43/"],"weaknesses":["CWE-79"],"ingestedAt":"2026-10-29T20:05:43.909Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2023/22xxx/CVE-2023-22932.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-22932","state":"PUBLISHED","datePublished":"2023-02-14T17:22:38.739Z","dateUpdated":"2025-02-28T11:03:57.639Z","assignerShortName":"Splunk","assignerOrgId":"42b59230-ec95-491e-8425-5a5befa1a469","dateReserved":"2023-01-10T21:39:55.583Z"},"containers":{"cna":{"title":"Persistent Cross-Site Scripting through a Base64-encoded Image in a View in Splunk Enterprise","descriptions":[{"lang":"en","value":"In Splunk Enterprise 9.0 versions before 9.0.4, a View allows for Cross-Site Scripting (XSS) through the error message in a Base64-encoded image. The vulnerability affects instances with Splunk Web enabled. It does not affect Splunk Enterprise versions below 9.0."}],"affected":[{"vendor":"Splunk","product":"Splunk Enterprise","versions":[{"version":"9.0","status":"affected","lessThan":"9.0.4","versionType":"custom"}]},{"vendor":"Splunk","product":"Splunk Cloud Platform","versions":[{"version":"-","status":"affected","lessThan":"9.0.2209.3","versionType":"custom"}]}],"references":[{"url":"https://advisory.splunk.com/advisories/SVD-2023-0202"},{"url":"https://research.splunk.com/application/ce6e1268-e01c-4df2-a617-0f034ed49a43/"}],"metrics":[{"cvssV3_1":{"vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:N","version":"3.1","baseScore":8,"baseSeverity":"HIGH"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-79","lang":"en","type":"cwe","description":"The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users."}]}],"providerMetadata":{"shortName":"Splunk","orgId":"42b59230-ec95-491e-8425-5a5befa1a469","dateUpdated":"2025-02-28T11:03:57.639Z"},"datePublic":"2023-02-14T00:00:00.000Z","source":{"advisory":"SVD-2023-0202"},"credits":[{"lang":"en","value":"Tim Coen (foobar7)"}]},"adp":[{"title":"CVE Program Container","references":[{"url":"https://advisory.splunk.com/advisories/SVD-2023-0202","tags":["x_transferred"]},{"url":"https://research.splunk.com/application/ce6e1268-e01c-4df2-a617-0f034ed49a43/","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-02T10:20:31.421Z"}}]}}}