{"id":"CVE-2023-22610","state":"PUBLISHED","title":"CVE-2023-22610","description":"\nA CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of\nService against the Geo SCADA server when specific messages are sent to the server over the\ndatabase server TCP port. \n\n\n\n","publishedAt":"2023-01-31T00:00:00.000Z","updatedAt":"2025-02-05T20:06:58.944Z","severity":{"score":9.1,"label":"Critical","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H","source":"schneider"},"assigner":"schneider","products":["Schneider Electric EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA)"],"affected":[{"vendor":"Schneider Electric","product":"EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA)","defaultStatus":"unaffected","versions":[{"version":"All","status":"affected","lessThan":"October 2022","versionType":"custom"}]}],"references":["https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf"],"weaknesses":["CWE-863"],"ingestedAt":"2026-10-29T20:05:43.909Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2023/22xxx/CVE-2023-22610.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-22610","state":"PUBLISHED","datePublished":"2023-01-31T00:00:00.000Z","dateUpdated":"2025-02-05T20:06:58.944Z","assignerShortName":"schneider","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateReserved":"2023-01-04T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"\nA CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of\nService against the Geo SCADA server when specific messages are sent to the server over the\ndatabase server TCP port. \n\n\n\n"}],"affected":[{"vendor":"Schneider Electric","product":"EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA)","defaultStatus":"unaffected","versions":[{"version":"All","status":"affected","lessThan":"October 2022","versionType":"custom"}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.1,"baseSeverity":"CRITICAL","confidentialityImpact":"NONE","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-863","description":"CWE-863 Incorrect Authorization","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"schneider","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateUpdated":"2023-06-14T07:17:44.658Z"},"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.0.9"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-02T10:13:49.385Z"}},{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-02-05T19:55:02.779459Z","id":"CVE-2023-22610","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-02-05T20:06:58.944Z"}}]}}}