{"id":"CVE-2023-1834","state":"PUBLISHED","title":"Rockwell Automation Kinetix 5500 Vulnerable to Open Port Exploitation","description":"\nRockwell Automation was made aware that Kinetix 5500 drives, manufactured between May 2022 and January 2023, and are running v7.13 may have the telnet and FTP ports open by default.  This could potentially allow attackers unauthorized access to the device through the open ports.","publishedAt":"2023-05-11T18:01:06.560Z","updatedAt":"2025-01-24T21:15:54.175Z","severity":{"score":9.4,"label":"Critical","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H","source":"Rockwell"},"assigner":"Rockwell","products":["Rockwell Automation Kinetix 5500 EtherNet/IP Servo Drive"],"affected":[{"vendor":"Rockwell Automation","product":"Kinetix 5500 EtherNet/IP Servo Drive","defaultStatus":"unaffected","versions":[{"version":"7.13","status":"affected"}]}],"references":["https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139441"],"weaknesses":["CWE-284"],"ingestedAt":"2026-10-29T20:05:36.141Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2023/1xxx/CVE-2023-1834.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-1834","state":"PUBLISHED","datePublished":"2023-05-11T18:01:06.560Z","dateUpdated":"2025-01-24T21:15:54.175Z","assignerShortName":"Rockwell","assignerOrgId":"b73dd486-f505-4403-b634-40b078b177f0","dateReserved":"2023-04-04T13:44:37.415Z"},"containers":{"cna":{"title":"Rockwell Automation Kinetix 5500 Vulnerable to Open Port Exploitation","descriptions":[{"lang":"en","value":"\nRockwell Automation was made aware that Kinetix 5500 drives, manufactured between May 2022 and January 2023, and are running v7.13 may have the telnet and FTP ports open by default.  This could potentially allow attackers unauthorized access to the device through the open ports."}],"affected":[{"vendor":"Rockwell Automation","product":"Kinetix 5500 EtherNet/IP Servo Drive","defaultStatus":"unaffected","versions":[{"version":"7.13","status":"affected"}]}],"references":[{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139441"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.4,"baseSeverity":"CRITICAL","confidentialityImpact":"LOW","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-284","description":"CWE-284 Improper Access Control","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"Rockwell","orgId":"b73dd486-f505-4403-b634-40b078b177f0","dateUpdated":"2023-05-11T18:01:06.560Z"},"impacts":[{"capecId":"CAPEC-1","descriptions":[{"lang":"en","value":"CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs"}]}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Customers should upgrade to v7.14 to correct the issue."}],"value":"Customers should upgrade to v7.14 to correct the issue."}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139441","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-02T06:05:26.633Z"}},{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-01-24T21:15:50.354200Z","id":"CVE-2023-1834","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-01-24T21:15:54.175Z"}}]}}}