{"id":"CVE-2023-0754","state":"PUBLISHED","title":"CVE-2023-0754","description":"\nThe affected products are vulnerable to an integer\noverflow or wraparound, which could  allow an attacker to crash the server and remotely\nexecute arbitrary code.\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n","publishedAt":"2023-02-23T21:27:09.964Z","updatedAt":"2025-01-16T21:55:46.607Z","severity":{"score":9.8,"label":"Critical","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","source":"icscert"},"assigner":"icscert","products":["PTC ThingWorx Edge C-SDK","Microsoft .NET-SDK","PTC ThingWorx Edge MicroServer (EMS)","PTC Kepware KEPServerEX","PTC ThingWorx Kepware Server ","PTC ThingWorx Industrial Connectivity","PTC ThingWorx Kepware Edge","Rockwell Automation  KEPServer Enterprise ","General Electric  Digital Industrial Gateway Server "],"affected":[{"vendor":"PTC","product":"ThingWorx Edge C-SDK","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"v2.2.12.1052 ","versionType":"custom"}]},{"vendor":"Microsoft","product":".NET-SDK","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"v5.8.4.971 ","versionType":"custom"}]},{"vendor":"PTC","product":"ThingWorx Edge MicroServer (EMS)","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"v5.4.10.0 ","versionType":"custom"}]},{"vendor":"PTC","product":"Kepware KEPServerEX","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"v6.12 ","versionType":"custom"}]},{"vendor":"PTC","product":"ThingWorx Kepware Server ","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"v6.12 ","versionType":"custom"}]},{"vendor":"PTC","product":"ThingWorx Industrial Connectivity","defaultStatus":"unaffected","versions":[{"version":"All Versions ","status":"affected"}]},{"vendor":"PTC","product":"ThingWorx Kepware Edge","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"v1.5","versionType":"custom"}]},{"vendor":"Rockwell Automation ","product":"KEPServer Enterprise ","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"v6.12","versionType":"custom"}]},{"vendor":"General Electric ","product":"Digital Industrial Gateway Server ","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"v7.612","versionType":"custom"}]}],"references":["https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01"],"weaknesses":["CWE-190"],"ingestedAt":"2026-10-29T20:05:36.141Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2023/0xxx/CVE-2023-0754.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-0754","state":"PUBLISHED","datePublished":"2023-02-23T21:27:09.964Z","dateUpdated":"2025-01-16T21:55:46.607Z","assignerShortName":"icscert","assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","dateReserved":"2023-02-08T20:15:58.394Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"\nThe affected products are vulnerable to an integer\noverflow or wraparound, which could  allow an attacker to crash the server and remotely\nexecute arbitrary code.\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n"}],"affected":[{"vendor":"PTC","product":"ThingWorx Edge C-SDK","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"v2.2.12.1052 ","versionType":"custom"}]},{"vendor":"Microsoft","product":".NET-SDK","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"v5.8.4.971 ","versionType":"custom"}]},{"vendor":"PTC","product":"ThingWorx Edge MicroServer (EMS)","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"v5.4.10.0 ","versionType":"custom"}]},{"vendor":"PTC","product":"Kepware KEPServerEX","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"v6.12 ","versionType":"custom"}]},{"vendor":"PTC","product":"ThingWorx Kepware Server ","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"v6.12 ","versionType":"custom"}]},{"vendor":"PTC","product":"ThingWorx Industrial Connectivity","defaultStatus":"unaffected","versions":[{"version":"All Versions ","status":"affected"}]},{"vendor":"PTC","product":"ThingWorx Kepware Edge","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"v1.5","versionType":"custom"}]},{"vendor":"Rockwell Automation ","product":"KEPServer Enterprise ","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"v6.12","versionType":"custom"}]},{"vendor":"General Electric ","product":"Digital Industrial Gateway Server ","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"v7.612","versionType":"custom"}]}],"references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-190","description":"CWE-190 Integer Overflow or Wraparound","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"icscert","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","dateUpdated":"2023-02-23T21:27:09.964Z"},"credits":[{"lang":"en","type":"finder","user":"00000000-0000-4000-9000-000000000000","value":"Chris Anastasio and Steven Seeley of Incite Team reported these vulnerabilities to CISA."}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>PTC has released the following resolutions:</p>\n\n<p>Update the impacted product to the latest version:</p>\n\n<p>· &nbsp; &nbsp; &nbsp; &nbsp;\nThingWorx Edge C-SDK: 3.0.0 or later.</p>\n\n<p>· &nbsp; &nbsp; &nbsp; &nbsp;\nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.</p>\n\n<p>· &nbsp; &nbsp; &nbsp; &nbsp;\n.NET-SDK: v5.8.5 or later.</p>\n\n<p>For Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is <b>not</b> enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:</p>\n\n<p>· &nbsp; &nbsp; &nbsp; &nbsp;\nKepware KEPServerEX: v6.13 or later.</p>\n\n<p>· &nbsp; &nbsp; &nbsp; &nbsp;\nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.</p>\n\n<p>· &nbsp; &nbsp; &nbsp; &nbsp;\nThingWorx Kepware Edge: v1.6 or later.</p>\n\n<p>The following products should be upgraded as indicated or in\naccordance with the applicable organization’s recommendations if the ThingWorx\nInterface is in use: </p>\n\n<p>· &nbsp; &nbsp; &nbsp; &nbsp;\nRockwell Automation KEPServer Enterprise: v6.13\nor later.</p>\n\n<p>· &nbsp; &nbsp; &nbsp; &nbsp;\nGE Digital Industrial Gateway Server: v7.613 or\nlater.</p>\n\n<p>For\nmore information see PTC’s <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/article/CS385715\">Customer Support Article\n</a>.</p>\n\n\n\n\n\n<br>"}],"value":"PTC has released the following resolutions:\n\n\n\nUpdate the impacted product to the latest version:\n\n\n\n·        \nThingWorx Edge C-SDK: 3.0.0 or later.\n\n\n\n·        \nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.\n\n\n\n·        \n.NET-SDK: v5.8.5 or later.\n\n\n\nFor Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is not enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:\n\n\n\n·        \nKepware KEPServerEX: v6.13 or later.\n\n\n\n·        \nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.\n\n\n\n·        \nThingWorx Kepware Edge: v1.6 or later.\n\n\n\nThe following products should be upgraded as indicated or in\naccordance with the applicable organization’s recommendations if the ThingWorx\nInterface is in use: \n\n\n\n·        \nRockwell Automation KEPServer Enterprise: v6.13\nor later.\n\n\n\n·        \nGE Digital Industrial Gateway Server: v7.613 or\nlater.\n\n\n\nFor\nmore information see PTC’s Customer Support Article\n.\n\n\n\n\n\n\n\n\n"}],"source":{"discovery":"EXTERNAL"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-02T05:24:34.053Z"}},{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-01-16T20:59:05.493845Z","id":"CVE-2023-0754","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-01-16T21:55:46.607Z"}}]}}}