{"id":"CVE-2022-50596","state":"PUBLISHED","title":"D-Link DIR-1260 <= v1.20B05 GetDeviceSettings Unauthenticated Command Injection","description":"D-Link DIR-1260 Wi-Fi router firmware versions up to and including v1.20B05 contain a command injection vulnerability within the web management interface that allows for unauthenticated attackers to execute arbitrary commands on the device with root privileges. The flaw specifically exists within the SetDest/Dest/Target arguments to the GetDeviceSettings form. The management interface is accessible over HTTP and HTTPS on the local and Wi-Fi networks and optionally from the Internet.","publishedAt":"2025-11-06T19:58:51.704Z","updatedAt":"2026-05-14T02:06:57.726Z","severity":{"score":9.3,"label":"Critical","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","source":"VulnCheck"},"assigner":"VulnCheck","products":["D-Link DIR-1260"],"affected":[{"vendor":"D-Link","product":"DIR-1260","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"1.20B05","versionType":"custom"}],"modules":["GetDeviceSettings form","SetDest/Dest/Target arguments"]}],"references":["https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10298","https://blog.exodusintel.com/2022/05/11/d-link-dir-1260-getdevicesettings-pre-auth-command-injection-vulnerability/","https://www.vulncheck.com/advisories/dlink-dir1260-getdevicesettings-unauthenticated-command-injection"],"weaknesses":["CWE-78"],"ingestedAt":"2026-10-29T20:05:26.763Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2022/50xxx/CVE-2022-50596.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2022-50596","state":"PUBLISHED","datePublished":"2025-11-06T19:58:51.704Z","dateUpdated":"2026-05-14T02:06:57.726Z","assignerShortName":"VulnCheck","assignerOrgId":"83251b91-4cc7-4094-a5c7-464a1b83ea10","dateReserved":"2025-11-05T16:58:35.657Z"},"containers":{"cna":{"title":"D-Link DIR-1260 <= v1.20B05 GetDeviceSettings Unauthenticated Command Injection","descriptions":[{"lang":"en","value":"D-Link DIR-1260 Wi-Fi router firmware versions up to and including v1.20B05 contain a command injection vulnerability within the web management interface that allows for unauthenticated attackers to execute arbitrary commands on the device with root privileges. The flaw specifically exists within the SetDest/Dest/Target arguments to the GetDeviceSettings form. The management interface is accessible over HTTP and HTTPS on the local and Wi-Fi networks and optionally from the Internet."}],"affected":[{"vendor":"D-Link","product":"DIR-1260","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"1.20B05","versionType":"custom"}],"modules":["GetDeviceSettings form","SetDest/Dest/Target arguments"]}],"references":[{"url":"https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10298","tags":["vendor-advisory","patch"]},{"url":"https://blog.exodusintel.com/2022/05/11/d-link-dir-1260-getdevicesettings-pre-auth-command-injection-vulnerability/","tags":["technical-description"]},{"url":"https://www.vulncheck.com/advisories/dlink-dir1260-getdevicesettings-unauthenticated-command-injection","tags":["third-party-advisory"]}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":9.3,"baseSeverity":"CRITICAL","exploitMaturity":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-78","description":"CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"VulnCheck","orgId":"83251b91-4cc7-4094-a5c7-464a1b83ea10","dateUpdated":"2026-05-14T02:06:57.726Z"},"cpeApplicability":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:dlink:dir-1260_firmware:-:*:*:*:*:*:*:*","versionEndIncluding":"1.20b05","versionStartIncluding":"0","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"}],"credits":[{"lang":"en","type":"finder","value":"Exodus Intelligence"}],"impacts":[{"capecId":"CAPEC-88","descriptions":[{"lang":"en","value":"CAPEC-88 OS Command Injection"}]}],"source":{"discovery":"UNKNOWN"},"timeline":[{"lang":"en","time":"2022-05-11T16:00:00.000Z","value":"Exodus Intelligence publicly discloses technical details of vulnerability."},{"lang":"en","time":"2022-05-05T16:00:00.000Z","value":"D-Link releases patched version - v1.02B06_Beta Hotfix."}],"x_generator":{"engine":"vulncheck"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-11-06T20:28:03.339394Z","id":"CVE-2022-50596","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-11-06T20:28:19.201Z"}}]}}}