{"id":"CVE-2022-46345","state":"PUBLISHED","title":"A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid","description":"A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19070)","publishedAt":"2022-12-13T00:00:00.000Z","updatedAt":"2024-08-03T14:31:46.241Z","severity":{"score":7.8,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","source":"siemens"},"assigner":"siemens","products":["Siemens Parasolid V33.1","Siemens Parasolid V34.0","Siemens Parasolid V34.1","Siemens Parasolid V35.0","Siemens Solid Edge SE2022","Siemens Solid Edge SE2023"],"affected":[{"vendor":"Siemens","product":"Parasolid V33.1","defaultStatus":"unknown","versions":[{"version":"All versions < V33.1.264","status":"affected"}]},{"vendor":"Siemens","product":"Parasolid V34.0","defaultStatus":"unknown","versions":[{"version":"All versions < V34.0.252","status":"affected"}]},{"vendor":"Siemens","product":"Parasolid V34.1","defaultStatus":"unknown","versions":[{"version":"All versions < V34.1.242","status":"affected"}]},{"vendor":"Siemens","product":"Parasolid V35.0","defaultStatus":"unknown","versions":[{"version":"All versions < V35.0.170","status":"affected"}]},{"vendor":"Siemens","product":"Solid Edge SE2022","defaultStatus":"unknown","versions":[{"version":"All versions < V222.0MP12","status":"affected"}]},{"vendor":"Siemens","product":"Solid Edge SE2022","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"Solid Edge SE2023","defaultStatus":"unknown","versions":[{"version":"All versions < V223.0Update2","status":"affected"}]}],"references":["https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf","https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"],"weaknesses":["CWE-787"],"ingestedAt":"2026-10-29T19:50:53.608Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2022/46xxx/CVE-2022-46345.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2022-46345","state":"PUBLISHED","datePublished":"2022-12-13T00:00:00.000Z","dateUpdated":"2024-08-03T14:31:46.241Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2022-11-30T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19070)"}],"affected":[{"vendor":"Siemens","product":"Parasolid V33.1","defaultStatus":"unknown","versions":[{"version":"All versions < V33.1.264","status":"affected"}]},{"vendor":"Siemens","product":"Parasolid V34.0","defaultStatus":"unknown","versions":[{"version":"All versions < V34.0.252","status":"affected"}]},{"vendor":"Siemens","product":"Parasolid V34.1","defaultStatus":"unknown","versions":[{"version":"All versions < V34.1.242","status":"affected"}]},{"vendor":"Siemens","product":"Parasolid V35.0","defaultStatus":"unknown","versions":[{"version":"All versions < V35.0.170","status":"affected"}]},{"vendor":"Siemens","product":"Solid Edge SE2022","defaultStatus":"unknown","versions":[{"version":"All versions < V222.0MP12","status":"affected"}]},{"vendor":"Siemens","product":"Solid Edge SE2022","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"Solid Edge SE2023","defaultStatus":"unknown","versions":[{"version":"All versions < V223.0Update2","status":"affected"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","baseScore":7.8,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-787","lang":"en","description":"CWE-787: Out-of-bounds Write","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2023-03-14T09:31:10.275Z"}},"adp":[{"title":"CISA ADP Vulnrichment","affected":[{"vendor":"siemens","product":"parasolid","defaultStatus":"unknown","versions":[{"version":"33.1","status":"affected","lessThan":"33.1.264","versionType":"custom"}],"cpes":["cpe:2.3:a:siemens:parasolid:33.1:*:*:*:*:*:*:*"]},{"vendor":"siemens","product":"solid_edge","defaultStatus":"unknown","versions":[{"version":"se2022","status":"affected","lessThan":"v223.0","versionType":"custom"}],"cpes":["cpe:2.3:a:siemens:solid_edge:se2022:-:*:*:*:*:*:*"]},{"vendor":"siemens","product":"parasolid","defaultStatus":"unknown","versions":[{"version":"34.1","status":"affected","lessThan":"34.1.242","versionType":"custom"}],"cpes":["cpe:2.3:a:siemens:parasolid:34.1:*:*:*:*:*:*:*"]},{"vendor":"siemens","product":"parasolid","defaultStatus":"unknown","versions":[{"version":"35.0","status":"affected","lessThan":"35.0.170","versionType":"custom"}],"cpes":["cpe:2.3:a:siemens:parasolid:35.0:*:*:*:*:*:*:*"]},{"vendor":"siemens","product":"parasolid","defaultStatus":"unknown","versions":[{"version":"34.0","status":"affected","lessThan":"34.0.252","versionType":"custom"}],"cpes":["cpe:2.3:a:siemens:parasolid:34.0:*:*:*:*:*:*:*"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-05-14T13:00:20.745055Z","id":"CVE-2022-46345","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-06-05T19:22:59.367Z"}},{"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf","tags":["x_transferred"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-03T14:31:46.241Z"}}]}}}