{"id":"CVE-2022-43376","state":"PUBLISHED","title":"CVE-2022-43376","description":"\n\n\nA CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site\nScripting') vulnerability exists that could cause code and session manipulation when malicious\ncode is inserted into the browser.\n\n Affected Products: NetBotz 4 - 355/450/455/550/570 (V4.7.0\n\n and prior)","publishedAt":"2023-04-18T19:55:07.347Z","updatedAt":"2025-02-05T20:05:07.304Z","severity":{"score":7.6,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:H/A:L","source":"schneider"},"assigner":"schneider","products":["Schneider Electric NetBotz 4 - 355/450/455/550/570"],"affected":[{"vendor":"Schneider Electric","product":"NetBotz 4 - 355/450/455/550/570","defaultStatus":"unaffected","versions":[{"version":"V4.7.0 and prior","status":"affected"}]}],"references":["https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-312-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-312-01-NetBotz_4_Security_Notification.pdf"],"weaknesses":["CWE-79"],"ingestedAt":"2026-10-29T19:50:43.581Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2022/43xxx/CVE-2022-43376.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2022-43376","state":"PUBLISHED","datePublished":"2023-04-18T19:55:07.347Z","dateUpdated":"2025-02-05T20:05:07.304Z","assignerShortName":"schneider","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateReserved":"2022-10-17T16:42:12.652Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"\n\n\nA CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site\nScripting') vulnerability exists that could cause code and session manipulation when malicious\ncode is inserted into the browser.\n\n Affected Products: NetBotz 4 - 355/450/455/550/570 (V4.7.0\n\n and prior)"}],"affected":[{"vendor":"Schneider Electric","product":"NetBotz 4 - 355/450/455/550/570","defaultStatus":"unaffected","versions":[{"version":"V4.7.0 and prior","status":"affected"}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-312-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-312-01-NetBotz_4_Security_Notification.pdf"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"LOW","baseScore":7.6,"baseSeverity":"HIGH","confidentialityImpact":"LOW","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:H/A:L","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-79","description":"CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"schneider","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateUpdated":"2023-04-18T19:55:07.347Z"},"datePublic":"2022-11-08T08:00:00.000Z","source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-312-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-312-01-NetBotz_4_Security_Notification.pdf","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-03T13:32:58.339Z"}},{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-02-05T19:50:33.636877Z","id":"CVE-2022-43376","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-02-05T20:05:07.304Z"}}]}}}