{"id":"CVE-2022-43110","state":"PUBLISHED","title":"Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauth","description":"Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down.","publishedAt":"2025-08-22T00:00:00.000Z","updatedAt":"2025-08-22T20:25:23.662Z","severity":{"score":9.8,"label":"Critical","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","source":"CISA-ADP"},"assigner":"mitre","products":["n/a n/a"],"affected":[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}],"references":["https://www.ready2disclose.com/vpow-31491-43110/","https://www.cisa.gov/news-events/ics-advisories/icsa-25-182-05"],"weaknesses":["CWE-425","CWE-306","CWE-284"],"ingestedAt":"2026-10-29T19:50:43.581Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2022/43xxx/CVE-2022-43110.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2022-43110","state":"PUBLISHED","datePublished":"2025-08-22T00:00:00.000Z","dateUpdated":"2025-08-22T20:25:23.662Z","assignerShortName":"mitre","assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","dateReserved":"2022-10-17T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down."}],"affected":[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}],"references":[{"url":"https://www.ready2disclose.com/vpow-31491-43110/"},{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-25-182-05"}],"problemTypes":[{"descriptions":[{"type":"text","lang":"en","description":"n/a"}]}],"providerMetadata":{"shortName":"mitre","orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","dateUpdated":"2025-08-22T19:34:35.786Z"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"cvssV3_1":{"scope":"UNCHANGED","version":"3.1","baseScore":9.8,"attackVector":"NETWORK","baseSeverity":"CRITICAL","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","integrityImpact":"HIGH","userInteraction":"NONE","attackComplexity":"LOW","availabilityImpact":"HIGH","privilegesRequired":"NONE","confidentialityImpact":"HIGH"}},{"other":{"type":"ssvc","content":{"timestamp":"2025-08-22T20:23:45.457505Z","id":"CVE-2022-43110","options":[{"Exploitation":"poc"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-425","type":"CWE","lang":"en","description":"CWE-425 Direct Request ('Forced Browsing')"}]},{"descriptions":[{"cweId":"CWE-306","type":"CWE","lang":"en","description":"CWE-306 Missing Authentication for Critical Function"}]},{"descriptions":[{"cweId":"CWE-284","type":"CWE","lang":"en","description":"CWE-284 Improper Access Control"}]}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-08-22T20:25:23.662Z"}}]}}}