{"id":"CVE-2022-42892","state":"PUBLISHED","title":"A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper write acce","description":"A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper write access control that could allow directory listing in any folder accessible to the account assigned to the website’s application pool.","publishedAt":"2022-11-17T00:00:00.000Z","updatedAt":"2025-04-30T14:40:44.703Z","severity":{"score":5.3,"label":"Medium","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","source":"CISA-ADP"},"assigner":"siemens","products":["Siemens syngo Dynamics"],"affected":[{"vendor":"Siemens","product":"syngo Dynamics","versions":[{"version":"All versions < VA40G HF01","status":"affected"}]}],"references":["https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"],"weaknesses":["CWE-23"],"ingestedAt":"2026-10-29T19:50:40.706Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2022/42xxx/CVE-2022-42892.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2022-42892","state":"PUBLISHED","datePublished":"2022-11-17T00:00:00.000Z","dateUpdated":"2025-04-30T14:40:44.703Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2022-10-12T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper write access control that could allow directory listing in any folder accessible to the account assigned to the website’s application pool."}],"affected":[{"vendor":"Siemens","product":"syngo Dynamics","versions":[{"version":"All versions < VA40G HF01","status":"affected"}]}],"references":[{"url":"https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"}],"problemTypes":[{"descriptions":[{"cweId":"CWE-23","type":"CWE","lang":"en","description":"CWE-23: Relative Path Traversal"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2022-11-17T00:00:00.000Z"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-03T13:19:05.491Z"}},{"title":"CISA ADP Vulnrichment","metrics":[{"cvssV3_1":{"scope":"UNCHANGED","version":"3.1","baseScore":5.3,"attackVector":"NETWORK","baseSeverity":"MEDIUM","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","integrityImpact":"NONE","userInteraction":"NONE","attackComplexity":"LOW","availabilityImpact":"NONE","privilegesRequired":"NONE","confidentialityImpact":"LOW"}},{"other":{"type":"ssvc","content":{"timestamp":"2025-04-30T14:40:14.911424Z","id":"CVE-2022-42892","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-04-30T14:40:44.703Z"}}]}}}