{"id":"CVE-2022-38767","state":"PUBLISHED","title":"An issue was discovered in Wind River VxWorks 6.9 and 7, that allows a specifically crafted packet sent by a Radius server, may cause Denial of Service during the IP Radius access ","description":"An issue was discovered in Wind River VxWorks 6.9 and 7, that allows a specifically crafted packet sent by a Radius server, may cause Denial of Service during the IP Radius access procedure.","publishedAt":"2022-11-25T00:00:00.000Z","updatedAt":"2026-04-14T08:58:05.041Z","severity":{"score":7.5,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","source":"CISA-ADP"},"assigner":"mitre","products":["n/a n/a"],"affected":[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}],"references":["https://windriver.com","https://support2.windriver.com/index.php?page=cve&on=view&id=CVE-2022-38767","https://cert-portal.siemens.com/productcert/html/ssa-726834.html"],"weaknesses":[],"ingestedAt":"2026-10-29T19:50:26.582Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2022/38xxx/CVE-2022-38767.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2022-38767","state":"PUBLISHED","datePublished":"2022-11-25T00:00:00.000Z","dateUpdated":"2026-04-14T08:58:05.041Z","assignerShortName":"mitre","assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","dateReserved":"2022-08-25T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"An issue was discovered in Wind River VxWorks 6.9 and 7, that allows a specifically crafted packet sent by a Radius server, may cause Denial of Service during the IP Radius access procedure."}],"affected":[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}],"references":[{"url":"https://windriver.com"},{"url":"https://support2.windriver.com/index.php?page=cve&on=view&id=CVE-2022-38767"}],"problemTypes":[{"descriptions":[{"type":"text","lang":"en","description":"n/a"}]}],"providerMetadata":{"shortName":"mitre","orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","dateUpdated":"2022-11-25T00:00:00.000Z"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://windriver.com","tags":["x_transferred"]},{"url":"https://support2.windriver.com/index.php?page=cve&on=view&id=CVE-2022-38767","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-03T11:02:14.648Z"}},{"title":"CISA ADP Vulnrichment","metrics":[{"cvssV3_1":{"scope":"UNCHANGED","version":"3.1","baseScore":7.5,"attackVector":"NETWORK","baseSeverity":"HIGH","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","integrityImpact":"NONE","userInteraction":"NONE","attackComplexity":"LOW","availabilityImpact":"HIGH","privilegesRequired":"NONE","confidentialityImpact":"NONE"}},{"other":{"type":"ssvc","content":{"timestamp":"2025-04-25T18:43:40.135126Z","id":"CVE-2022-38767","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"problemTypes":[{"descriptions":[{"type":"CWE","lang":"en","description":"CWE-noinfo Not enough information"}]}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-04-25T18:44:18.928Z"}},{"affected":[{"vendor":"Siemens","product":"SIPROTEC 5 6MD85 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V9.30","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 6MD86 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V9.30","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 6MD89 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V9.64","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 6MU85 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.90","status":"affected","lessThan":"V9.30","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7KE85 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V9.30","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SA86 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V9.30","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SA87 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V9.30","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SD86 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V9.30","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SD87 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V9.30","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SJ85 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V9.30","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SJ86 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V9.30","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SK85 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V9.30","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SL86 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V9.30","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SL87 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V9.30","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SS85 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V9.30","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7ST85 (CP300)","defaultStatus":"unknown","versions":[{"version":"V8.81","status":"affected","lessThan":"V9.30","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7ST86 (CP300)","defaultStatus":"unknown","versions":[{"version":"V9.20","status":"affected","lessThan":"V9.30","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7SX85 (CP300)","defaultStatus":"unknown","versions":[{"version":"V8.30","status":"affected","lessThan":"V9.30","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7UM85 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V9.30","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7UT85 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V9.30","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7UT86 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V9.30","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7UT87 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V9.30","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7VE85 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V9.30","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 7VK87 (CP300)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V9.30","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V9.30","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1)","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V9.30","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 Communication Module ETH-BD-2FO","defaultStatus":"unknown","versions":[{"version":"V7.80","status":"affected","lessThan":"V9.30","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPROTEC 5 Compact 7SX800 (CP050)","defaultStatus":"unknown","versions":[{"version":"V8.70","status":"affected","lessThan":"V9.30","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-726834.html"}],"providerMetadata":{"shortName":"siemens-SADP","orgId":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","dateUpdated":"2026-04-14T08:58:05.041Z"},"x_adpType":"supplier"}]}}}