{"id":"CVE-2022-35927","state":"PUBLISHED","title":"Unverified DIO prefix info lengths in RPL-Classic in Contiki-NG","description":"Contiki-NG is an open-source, cross-platform operating system for IoT devices. In the RPL-Classic routing protocol implementation in the Contiki-NG operating system, an incoming DODAG Information Option (DIO) control message can contain a prefix information option with a length parameter. The value of the length parameter is not validated, however, and it is possible to cause a buffer overflow when copying the prefix in the set_ip_from_prefix function. This vulnerability affects anyone running a Contiki-NG version prior to 4.7 that can receive RPL DIO messages from external parties. To obtain a patched version, users should upgrade to Contiki-NG 4.7 or later. There are no workarounds for this issue.","publishedAt":"2022-08-04T20:35:14.000Z","updatedAt":"2025-04-23T17:53:22.094Z","severity":{"score":8.1,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","source":"GitHub_M"},"assigner":"GitHub_M","products":["contiki-ng contiki-ng"],"affected":[{"vendor":"contiki-ng","product":"contiki-ng","versions":[{"version":"< 4.7","status":"affected"}]}],"references":["https://github.com/contiki-ng/contiki-ng/security/advisories/GHSA-9rm9-3phh-p4wm","https://github.com/contiki-ng/contiki-ng/pull/1589","https://github.com/contiki-ng/contiki-ng/pull/1589/commits/4fffab0e632c4d01910fa957d1fd9ef321eb87d2"],"weaknesses":["CWE-120"],"ingestedAt":"2026-10-29T19:50:17.761Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2022/35xxx/CVE-2022-35927.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2022-35927","state":"PUBLISHED","datePublished":"2022-08-04T20:35:14.000Z","dateUpdated":"2025-04-23T17:53:22.094Z","assignerShortName":"GitHub_M","assignerOrgId":"a0819718-46f1-4df5-94e2-005712e83aaa","dateReserved":"2022-07-15T00:00:00.000Z"},"containers":{"cna":{"title":"Unverified DIO prefix info lengths in RPL-Classic in Contiki-NG","descriptions":[{"lang":"en","value":"Contiki-NG is an open-source, cross-platform operating system for IoT devices. In the RPL-Classic routing protocol implementation in the Contiki-NG operating system, an incoming DODAG Information Option (DIO) control message can contain a prefix information option with a length parameter. The value of the length parameter is not validated, however, and it is possible to cause a buffer overflow when copying the prefix in the set_ip_from_prefix function. This vulnerability affects anyone running a Contiki-NG version prior to 4.7 that can receive RPL DIO messages from external parties. To obtain a patched version, users should upgrade to Contiki-NG 4.7 or later. There are no workarounds for this issue."}],"affected":[{"vendor":"contiki-ng","product":"contiki-ng","versions":[{"version":"< 4.7","status":"affected"}]}],"references":[{"url":"https://github.com/contiki-ng/contiki-ng/security/advisories/GHSA-9rm9-3phh-p4wm","tags":["x_refsource_CONFIRM"]},{"url":"https://github.com/contiki-ng/contiki-ng/pull/1589","tags":["x_refsource_MISC"]},{"url":"https://github.com/contiki-ng/contiki-ng/pull/1589/commits/4fffab0e632c4d01910fa957d1fd9ef321eb87d2","tags":["x_refsource_MISC"]}],"metrics":[{"cvssV3_1":{"attackComplexity":"HIGH","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8.1,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-120","description":"CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"GitHub_M","dateUpdated":"2022-08-04T20:35:14.000Z","orgId":"a0819718-46f1-4df5-94e2-005712e83aaa"},"source":{"advisory":"GHSA-9rm9-3phh-p4wm","discovery":"UNKNOWN"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"security-advisories@github.com","ID":"CVE-2022-35927","STATE":"PUBLIC","TITLE":"Unverified DIO prefix info lengths in RPL-Classic in Contiki-NG"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"contiki-ng","version":{"version_data":[{"version_value":"< 4.7"}]}}]},"vendor_name":"contiki-ng"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Contiki-NG is an open-source, cross-platform operating system for IoT devices. In the RPL-Classic routing protocol implementation in the Contiki-NG operating system, an incoming DODAG Information Option (DIO) control message can contain a prefix information option with a length parameter. The value of the length parameter is not validated, however, and it is possible to cause a buffer overflow when copying the prefix in the set_ip_from_prefix function. This vulnerability affects anyone running a Contiki-NG version prior to 4.7 that can receive RPL DIO messages from external parties. To obtain a patched version, users should upgrade to Contiki-NG 4.7 or later. There are no workarounds for this issue."}]},"impact":{"cvss":{"attackComplexity":"HIGH","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8.1,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')"}]}]},"references":{"reference_data":[{"name":"https://github.com/contiki-ng/contiki-ng/security/advisories/GHSA-9rm9-3phh-p4wm","refsource":"CONFIRM","url":"https://github.com/contiki-ng/contiki-ng/security/advisories/GHSA-9rm9-3phh-p4wm"},{"name":"https://github.com/contiki-ng/contiki-ng/pull/1589","refsource":"MISC","url":"https://github.com/contiki-ng/contiki-ng/pull/1589"},{"name":"https://github.com/contiki-ng/contiki-ng/pull/1589/commits/4fffab0e632c4d01910fa957d1fd9ef321eb87d2","refsource":"MISC","url":"https://github.com/contiki-ng/contiki-ng/pull/1589/commits/4fffab0e632c4d01910fa957d1fd9ef321eb87d2"}]},"source":{"advisory":"GHSA-9rm9-3phh-p4wm","discovery":"UNKNOWN"}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://github.com/contiki-ng/contiki-ng/security/advisories/GHSA-9rm9-3phh-p4wm","tags":["x_refsource_CONFIRM","x_transferred"]},{"url":"https://github.com/contiki-ng/contiki-ng/pull/1589","tags":["x_refsource_MISC","x_transferred"]},{"url":"https://github.com/contiki-ng/contiki-ng/pull/1589/commits/4fffab0e632c4d01910fa957d1fd9ef321eb87d2","tags":["x_refsource_MISC","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-03T09:51:59.029Z"}},{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-04-23T15:51:03.682591Z","id":"CVE-2022-35927","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-04-23T17:53:22.094Z"}}]}}}