{"id":"CVE-2022-34758","state":"PUBLISHED","title":"A CWE-20: Improper Input Validation vulnerability exists that could cause the device watchdog function to be disabled if the attacker had access to privileged user credentials. Aff","description":"A CWE-20: Improper Input Validation vulnerability exists that could cause the device watchdog function to be disabled if the attacker had access to privileged user credentials. Affected Products: Easergy P5 (V01.401.102 and prior)","publishedAt":"2022-07-13T21:10:41.744Z","updatedAt":"2024-09-17T00:50:40.234Z","severity":{"score":5.1,"label":"Medium","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:L","source":"schneider"},"assigner":"schneider","products":["Schneider Electric Easergy P5"],"affected":[{"vendor":"Schneider Electric","product":"Easergy P5","versions":[{"version":"Firmware","status":"affected","lessThan":"V01.401.102","versionType":"custom"}]}],"references":["https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-193-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-193-04_Easergy_P5_Security_Notification.pdf"],"weaknesses":["CWE-20"],"ingestedAt":"2026-10-29T19:50:14.780Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2022/34xxx/CVE-2022-34758.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2022-34758","state":"PUBLISHED","datePublished":"2022-07-13T21:10:41.744Z","dateUpdated":"2024-09-17T00:50:40.234Z","assignerShortName":"schneider","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateReserved":"2022-06-28T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A CWE-20: Improper Input Validation vulnerability exists that could cause the device watchdog function to be disabled if the attacker had access to privileged user credentials. Affected Products: Easergy P5 (V01.401.102 and prior)"}],"affected":[{"vendor":"Schneider Electric","product":"Easergy P5","versions":[{"version":"Firmware","status":"affected","lessThan":"V01.401.102","versionType":"custom"}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-193-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-193-04_Easergy_P5_Security_Notification.pdf","tags":["x_refsource_MISC"]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"LOW","baseScore":5.1,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"HIGH","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:L","version":"3.1"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-20","description":"CWE-20 Improper Input Validation","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"schneider","dateUpdated":"2022-07-13T21:10:41.000Z","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb"},"datePublic":"2022-07-12T00:00:00.000Z","source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.0.9"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@schneider-electric.com","DATE_PUBLIC":"2022-07-12T11:00:00.000Z","ID":"CVE-2022-34758","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Easergy P5","version":{"version_data":[{"version_affected":"<","version_name":"Firmware","version_value":"V01.401.102"}]}}]},"vendor_name":"Schneider Electric"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A CWE-20: Improper Input Validation vulnerability exists that could cause the device watchdog function to be disabled if the attacker had access to privileged user credentials. Affected Products: Easergy P5 (V01.401.102 and prior)"}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"LOW","baseScore":5.1,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"HIGH","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:L","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-20 Improper Input Validation"}]}]},"references":{"reference_data":[{"name":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-193-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-193-04_Easergy_P5_Security_Notification.pdf","refsource":"MISC","url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-193-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-193-04_Easergy_P5_Security_Notification.pdf"}]},"source":{"discovery":"UNKNOWN"}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-193-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-193-04_Easergy_P5_Security_Notification.pdf","tags":["x_refsource_MISC","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-03T09:22:09.247Z"}}]}}}