{"id":"CVE-2022-32253","state":"PUBLISHED","title":"A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). Due to improper input validation, the OpenSSL certificate's password could be printed to ","description":"A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). Due to improper input validation, the OpenSSL certificate's password could be printed to a file reachable by an attacker.","publishedAt":"2022-06-14T09:22:04.000Z","updatedAt":"2024-08-03T07:39:50.216Z","severity":{"score":4.9,"label":"Medium","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C","source":"siemens"},"assigner":"siemens","products":["Siemens SINEMA Remote Connect Server"],"affected":[{"vendor":"Siemens","product":"SINEMA Remote Connect Server","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.1","versionType":"custom"}]}],"references":["https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf","https://cert-portal.siemens.com/productcert/html/ssa-484086.html"],"weaknesses":["CWE-20"],"ingestedAt":"2026-10-29T19:50:09.278Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2022/32xxx/CVE-2022-32253.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2022-32253","state":"PUBLISHED","datePublished":"2022-06-14T09:22:04.000Z","dateUpdated":"2024-08-03T07:39:50.216Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2022-06-02T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). Due to improper input validation, the OpenSSL certificate's password could be printed to a file reachable by an attacker."}],"affected":[{"vendor":"Siemens","product":"SINEMA Remote Connect Server","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.1","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf","tags":["x_refsource_MISC"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-484086.html"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C","baseScore":4.9,"baseSeverity":"MEDIUM"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-20","lang":"en","description":"CWE-20: Improper Input Validation","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2024-07-09T12:04:09.589Z"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf","tags":["x_refsource_MISC","x_transferred"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-484086.html","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-03T07:39:50.216Z"}}]}}}