{"id":"CVE-2022-3156","state":"PUBLISHED","title":"Rockwell Automation Studio 5000 Logix Emulate Vulnerable to a Remote Code Execution Vulnerability","description":"A remote code execution vulnerability exists in Rockwell Automation Studio 5000 Logix Emulate software.  Users are granted elevated permissions on certain product services when the software is installed. Due to \nthis misconfiguration, a malicious user could potentially achieve remote code execution on the targeted software.\n\n \n\n\n","publishedAt":"2022-12-27T18:17:50.219Z","updatedAt":"2025-04-10T20:06:21.915Z","severity":{"score":7.8,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","source":"Rockwell"},"assigner":"Rockwell","products":["Rockwell Automation Studio 5000 Logix Emulate"],"affected":[{"vendor":"Rockwell Automation","product":"Studio 5000 Logix Emulate","defaultStatus":"unaffected","versions":[{"version":"20.011 ","status":"affected","lessThanOrEqual":"33.011","versionType":"Major"}]}],"references":["https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137846"],"weaknesses":["CWE-287"],"ingestedAt":"2026-10-29T19:50:32.060Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2022/3xxx/CVE-2022-3156.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2022-3156","state":"PUBLISHED","datePublished":"2022-12-27T18:17:50.219Z","dateUpdated":"2025-04-10T20:06:21.915Z","assignerShortName":"Rockwell","assignerOrgId":"b73dd486-f505-4403-b634-40b078b177f0","dateReserved":"2022-09-07T18:58:07.407Z"},"containers":{"cna":{"title":"Rockwell Automation Studio 5000 Logix Emulate Vulnerable to a Remote Code Execution Vulnerability","descriptions":[{"lang":"en","value":"A remote code execution vulnerability exists in Rockwell Automation Studio 5000 Logix Emulate software.  Users are granted elevated permissions on certain product services when the software is installed. Due to \nthis misconfiguration, a malicious user could potentially achieve remote code execution on the targeted software.\n\n \n\n\n"}],"affected":[{"vendor":"Rockwell Automation","product":"Studio 5000 Logix Emulate","defaultStatus":"unaffected","versions":[{"version":"20.011 ","status":"affected","lessThanOrEqual":"33.011","versionType":"Major"}]}],"references":[{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137846"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-287","description":"CWE-287 Improper Authentication","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"Rockwell","orgId":"b73dd486-f505-4403-b634-40b078b177f0","dateUpdated":"2022-12-27T18:17:50.219Z"},"datePublic":"2022-12-22T15:00:00.000Z","impacts":[{"capecId":"CAPEC-122","descriptions":[{"lang":"en","value":"CAPEC-122 Privilege Abuse"}]}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137846","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-03T01:00:10.643Z"}},{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-04-10T20:05:43.136419Z","id":"CVE-2022-3156","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-04-10T20:06:21.915Z"}}]}}}