{"id":"CVE-2022-30694","state":"PUBLISHED","title":"The login endpoint /FormLogin in affected web services does not apply proper origin checking.\r","description":"The login endpoint /FormLogin in affected web services does not apply proper origin checking.\r\n\r\nThis could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack.","publishedAt":"2022-11-08T00:00:00.000Z","updatedAt":"2025-04-21T13:47:33.635Z","severity":{"score":6.5,"label":"Medium","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C","source":"siemens"},"assigner":"siemens","products":["Siemens SIMATIC Drive Controller CPU 1504D TF","Siemens SIMATIC Drive Controller CPU 1507D TF","Siemens SIMATIC ET 200pro IM154-8 PN/DP CPU","Siemens SIMATIC ET 200pro IM154-8F PN/DP CPU","Siemens SIMATIC ET 200pro IM154-8FX PN/DP CPU","Siemens SIMATIC ET 200S IM151-8 PN/DP CPU","Siemens SIMATIC ET 200S IM151-8F PN/DP CPU","Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)","Siemens SIMATIC PC Station","Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants)","Siemens SIMATIC S7-1500 CPU 1510SP F-1 PN","Siemens SIMATIC S7-1500 CPU 1510SP-1 PN","Siemens SIMATIC S7-1500 CPU 1511-1 PN","Siemens SIMATIC S7-1500 CPU 1511C-1 PN","Siemens SIMATIC S7-1500 CPU 1511F-1 PN","Siemens SIMATIC S7-1500 CPU 1511T-1 PN","Siemens SIMATIC S7-1500 CPU 1511TF-1 PN","Siemens SIMATIC S7-1500 CPU 1512C-1 PN","Siemens SIMATIC S7-1500 CPU 1512SP F-1 PN","Siemens SIMATIC S7-1500 CPU 1512SP-1 PN","Siemens SIMATIC S7-1500 CPU 1513-1 PN","Siemens SIMATIC S7-1500 CPU 1513F-1 PN","Siemens SIMATIC S7-1500 CPU 1513R-1 PN","Siemens SIMATIC S7-1500 CPU 1515-2 PN","Siemens SIMATIC S7-1500 CPU 1515F-2 PN","Siemens SIMATIC S7-1500 CPU 1515R-2 PN","Siemens SIMATIC S7-1500 CPU 1515T-2 PN","Siemens SIMATIC S7-1500 CPU 1515TF-2 PN","Siemens SIMATIC S7-1500 CPU 1516-3 PN/DP","Siemens SIMATIC S7-1500 CPU 1516F-3 PN/DP","Siemens SIMATIC S7-1500 CPU 1516T-3 PN/DP","Siemens SIMATIC S7-1500 CPU 1516TF-3 PN/DP","Siemens SIMATIC S7-1500 CPU 1517-3 PN/DP","Siemens SIMATIC S7-1500 CPU 1517F-3 PN/DP","Siemens SIMATIC S7-1500 CPU 1517H-3 PN","Siemens SIMATIC S7-1500 CPU 1517T-3 PN/DP","Siemens SIMATIC S7-1500 CPU 1517TF-3 PN/DP","Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP","Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP","Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP","Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP","Siemens SIMATIC S7-1500 CPU 1518HF-4 PN","Siemens SIMATIC S7-1500 CPU 1518T-4 PN/DP","Siemens SIMATIC S7-1500 CPU 1518TF-4 PN/DP","Siemens SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK","Siemens SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK","Siemens SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN","Siemens SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN","Siemens SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN","Siemens SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN","Siemens SIMATIC S7-1500 Software Controller V2","Siemens SIMATIC S7-300 CPU 314C-2 PN/DP","Siemens SIMATIC S7-300 CPU 315-2 PN/DP","Siemens SIMATIC S7-300 CPU 315F-2 PN/DP","Siemens SIMATIC S7-300 CPU 315T-3 PN/DP","Siemens SIMATIC S7-300 CPU 317-2 PN/DP","Siemens SIMATIC S7-300 CPU 317F-2 PN/DP","Siemens SIMATIC S7-300 CPU 317T-3 PN/DP","Siemens SIMATIC S7-300 CPU 317TF-3 PN/DP","Siemens SIMATIC S7-300 CPU 319-3 PN/DP","Siemens SIMATIC S7-300 CPU 319F-3 PN/DP","Siemens SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)","Siemens SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)","Siemens SIMATIC S7-PLCSIM Advanced","Siemens SIMATIC WinCC Runtime Advanced","Siemens SINUMERIK ONE","Siemens SIPLUS ET 200S IM151-8 PN/DP CPU","Siemens SIPLUS ET 200S IM151-8F PN/DP CPU","Siemens SIPLUS ET 200SP CPU 1510SP F-1 PN","Siemens SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL","Siemens SIPLUS ET 200SP CPU 1510SP-1 PN","Siemens SIPLUS ET 200SP CPU 1510SP-1 PN RAIL","Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN","Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL","Siemens SIPLUS ET 200SP CPU 1512SP-1 PN","Siemens SIPLUS ET 200SP CPU 1512SP-1 PN RAIL","Siemens SIPLUS S7-1500 CPU 1511-1 PN","Siemens SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL","Siemens SIPLUS S7-1500 CPU 1511-1 PN TX RAIL","Siemens SIPLUS S7-1500 CPU 1511F-1 PN","Siemens SIPLUS S7-1500 CPU 1513-1 PN","Siemens SIPLUS S7-1500 CPU 1513F-1 PN","Siemens SIPLUS S7-1500 CPU 1515F-2 PN","Siemens SIPLUS S7-1500 CPU 1515F-2 PN RAIL","Siemens SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL","Siemens SIPLUS S7-1500 CPU 1515R-2 PN","Siemens SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL","Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP","Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL","Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL","Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP","Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL","Siemens SIPLUS S7-1500 CPU 1517H-3 PN","Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP","Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP","Siemens SIPLUS S7-1500 CPU 1518F-4 PN/DP","Siemens SIPLUS S7-1500 CPU 1518HF-4 PN","Siemens SIPLUS S7-300 CPU 314C-2 PN/DP","Siemens SIPLUS S7-300 CPU 315-2 PN/DP","Siemens SIPLUS S7-300 CPU 315F-2 PN/DP","Siemens SIPLUS S7-300 CPU 317-2 PN/DP","Siemens SIPLUS S7-300 CPU 317F-2 PN/DP"],"affected":[{"vendor":"Siemens","product":"SIMATIC Drive Controller CPU 1504D TF","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC Drive Controller CPU 1507D TF","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200pro IM154-8 PN/DP CPU","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200pro IM154-8F PN/DP CPU","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200pro IM154-8FX PN/DP CPU","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200S IM151-8 PN/DP CPU","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200S IM151-8F PN/DP CPU","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V21.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC PC Station","defaultStatus":"unknown","versions":[{"version":"All versions >= V2.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1200 CPU family (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V4.6.0","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1510SP F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1510SP F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1510SP-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1510SP-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511C-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511C-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511T-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511TF-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1512C-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1512C-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1512SP F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1512SP F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1512SP-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1512SP-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1513-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1513-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1513-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1513F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1513F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1513F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1513R-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1515-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1515-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1515-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1515F-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1515F-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1515F-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1515R-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1515T-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1515TF-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1516F-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1516F-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1516F-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1516T-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1516TF-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1517-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1517F-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1517H-3 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1517T-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1517TF-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518-4 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518-4 PN/DP MFP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518F-4 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518HF-4 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518T-4 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518TF-4 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 Software Controller V2","defaultStatus":"unknown","versions":[{"version":"All versions < V21.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 314C-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.3.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 315-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 315F-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 315T-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 317-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 317F-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 317T-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 317TF-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 319-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 319F-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-PLCSIM Advanced","defaultStatus":"unknown","versions":[{"version":"All versions < V5.0","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC WinCC Runtime Advanced","defaultStatus":"unknown","versions":[{"version":"All versions < V17 Update 5","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK ONE","defaultStatus":"unknown","versions":[{"version":"All versions < V6.22","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200S IM151-8 PN/DP CPU","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200S IM151-8F PN/DP CPU","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1510SP F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1510SP-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1510SP-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1510SP-1 PN RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1510SP-1 PN RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1512SP F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1512SP F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1512SP F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1512SP-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1512SP-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1512SP-1 PN RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1512SP-1 PN RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511-1 PN TX RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511-1 PN TX RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1513-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1513-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1513-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1513-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1513-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1513F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1513F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1513F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1515F-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1515F-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1515F-2 PN RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1515R-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516F-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516F-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516F-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1517H-3 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1518-4 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1518-4 PN/DP MFP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1518F-4 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1518HF-4 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-300 CPU 314C-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.3.19","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-300 CPU 315-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-300 CPU 315F-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-300 CPU 317-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-300 CPU 317F-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]}],"references":["https://cert-portal.siemens.com/productcert/pdf/ssa-478960.pdf"],"weaknesses":["CWE-352"],"ingestedAt":"2026-10-29T19:50:04.052Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2022/30xxx/CVE-2022-30694.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2022-30694","state":"PUBLISHED","datePublished":"2022-11-08T00:00:00.000Z","dateUpdated":"2025-04-21T13:47:33.635Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2022-05-13T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"The login endpoint /FormLogin in affected web services does not apply proper origin checking.\r\n\r\nThis could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack."}],"affected":[{"vendor":"Siemens","product":"SIMATIC Drive Controller CPU 1504D TF","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC Drive Controller CPU 1507D TF","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200pro IM154-8 PN/DP CPU","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200pro IM154-8F PN/DP CPU","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200pro IM154-8FX PN/DP CPU","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200S IM151-8 PN/DP CPU","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200S IM151-8F PN/DP CPU","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V21.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC PC Station","defaultStatus":"unknown","versions":[{"version":"All versions >= V2.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1200 CPU family (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions < V4.6.0","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1510SP F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1510SP F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1510SP-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1510SP-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511C-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511C-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511T-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511TF-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1512C-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1512C-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1512SP F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1512SP F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1512SP-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1512SP-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1513-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1513-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1513-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1513F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1513F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1513F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1513R-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1515-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1515-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1515-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1515F-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1515F-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1515F-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1515R-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1515T-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1515TF-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1516F-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1516F-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1516F-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1516T-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1516TF-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1517-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1517F-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1517H-3 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1517T-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1517TF-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518-4 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518-4 PN/DP MFP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518F-4 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518HF-4 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518T-4 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518TF-4 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-1500 Software Controller V2","defaultStatus":"unknown","versions":[{"version":"All versions < V21.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 314C-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.3.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 315-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 315F-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 315T-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 317-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 317F-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 317T-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 317TF-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 319-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU 319F-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC S7-PLCSIM Advanced","defaultStatus":"unknown","versions":[{"version":"All versions < V5.0","status":"affected"}]},{"vendor":"Siemens","product":"SIMATIC WinCC Runtime Advanced","defaultStatus":"unknown","versions":[{"version":"All versions < V17 Update 5","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK ONE","defaultStatus":"unknown","versions":[{"version":"All versions < V6.22","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200S IM151-8 PN/DP CPU","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200S IM151-8F PN/DP CPU","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1510SP F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1510SP-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1510SP-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1510SP-1 PN RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1510SP-1 PN RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1512SP F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1512SP F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1512SP F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1512SP-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1512SP-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1512SP-1 PN RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1512SP-1 PN RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511-1 PN TX RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511-1 PN TX RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1513-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1513-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1513-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1513-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1513-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1513F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1513F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1513F-1 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1515F-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1515F-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1515F-2 PN RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1515R-2 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516F-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516F-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516F-3 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL","defaultStatus":"unknown","versions":[{"version":"All versions < V2.9.7","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1517H-3 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1518-4 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1518-4 PN/DP MFP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1518F-4 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1518HF-4 PN","defaultStatus":"unknown","versions":[{"version":"All versions < V3.0.1","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-300 CPU 314C-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.3.19","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-300 CPU 315-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-300 CPU 315F-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-300 CPU 317-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]},{"vendor":"Siemens","product":"SIPLUS S7-300 CPU 317F-2 PN/DP","defaultStatus":"unknown","versions":[{"version":"All versions < V3.2.19","status":"affected"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-478960.pdf"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C","baseScore":6.5,"baseSeverity":"MEDIUM"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-352","lang":"en","description":"CWE-352: Cross-Site Request Forgery (CSRF)","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2023-09-12T09:31:58.151Z"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-478960.pdf","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-03T06:56:13.567Z"}},{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-04-18T15:15:21.439962Z","id":"CVE-2022-30694","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-04-21T13:47:33.635Z"}}]}}}