{"id":"CVE-2022-29875","state":"PUBLISHED","title":"A vulnerability has been identified in Biograph Horizon PET/CT Systems (All VJ30 versions < VJ30C-UD01), MAGNETOM Family (NUMARIS X: VA12M, VA12S, VA10B, VA20A, VA30A, VA31A), MAMM","description":"A vulnerability has been identified in Biograph Horizon PET/CT Systems (All VJ30 versions < VJ30C-UD01), MAGNETOM Family (NUMARIS X: VA12M, VA12S, VA10B, VA20A, VA30A, VA31A), MAMMOMAT Revelation (All VC20 versions < VC20D), NAEOTOM Alpha (All VA40 versions < VA40 SP2), SOMATOM X.cite (All versions < VA30 SP5 or VA40 SP2), SOMATOM X.creed (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.All (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Now (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Open Pro (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Sim (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Top (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Up (All versions < VA30 SP5 or VA40 SP2), Symbia E/S (All VB22 versions < VB22A-UD03), Symbia Evo (All VB22 versions < VB22A-UD03), Symbia Intevo (All VB22 versions < VB22A-UD03), Symbia T (All VB22 versions < VB22A-UD03), Symbia.net (All VB22 versions < VB22A-UD03), syngo.via VB10 (All versions), syngo.via VB20 (All versions), syngo.via VB30 (All versions), syngo.via VB40 (All versions < VB40B HF06), syngo.via VB50 (All versions), syngo.via VB60 (All versions < VB60B HF02). The application deserialises untrusted data without sufficient validations that could result in an arbitrary deserialization. This could allow an unauthenticated attacker to execute code in the affected system if ports 32912/tcp or 32914/tcp are reachable.","publishedAt":"2022-06-01T09:50:11.000Z","updatedAt":"2024-08-03T06:33:42.999Z","severity":null,"assigner":"siemens","products":["Siemens Biograph Horizon PET/CT Systems","Siemens MAGNETOM Family","Siemens MAMMOMAT Revelation","Siemens NAEOTOM Alpha","Siemens SOMATOM X.cite","Siemens SOMATOM X.creed","Siemens SOMATOM go.All","Siemens SOMATOM go.Now","Siemens SOMATOM go.Open Pro","Siemens SOMATOM go.Sim","Siemens SOMATOM go.Top","Siemens SOMATOM go.Up","Siemens Symbia E/S","Siemens Symbia Evo","Siemens Symbia Intevo","Siemens Symbia T","Siemens Symbia.net","Siemens syngo.via VB10","Siemens syngo.via VB20","Siemens syngo.via VB30","Siemens syngo.via VB40","Siemens syngo.via VB50","Siemens syngo.via VB60"],"affected":[{"vendor":"Siemens","product":"Biograph Horizon PET/CT Systems","versions":[{"version":"All VJ30 versions < VJ30C-UD01","status":"affected"}]},{"vendor":"Siemens","product":"MAGNETOM Family","versions":[{"version":"NUMARIS X: VA12M, VA12S, VA10B, VA20A, VA30A, VA31A","status":"affected"}]},{"vendor":"Siemens","product":"MAMMOMAT Revelation","versions":[{"version":"All VC20 versions < VC20D","status":"affected"}]},{"vendor":"Siemens","product":"NAEOTOM Alpha","versions":[{"version":"All VA40 versions < VA40 SP2","status":"affected"}]},{"vendor":"Siemens","product":"SOMATOM X.cite","versions":[{"version":"All versions < VA30 SP5 or VA40 SP2","status":"affected"}]},{"vendor":"Siemens","product":"SOMATOM X.creed","versions":[{"version":"All versions < VA30 SP5 or VA40 SP2","status":"affected"}]},{"vendor":"Siemens","product":"SOMATOM go.All","versions":[{"version":"All versions < VA30 SP5 or VA40 SP2","status":"affected"}]},{"vendor":"Siemens","product":"SOMATOM go.Now","versions":[{"version":"All versions < VA30 SP5 or VA40 SP2","status":"affected"}]},{"vendor":"Siemens","product":"SOMATOM go.Open Pro","versions":[{"version":"All versions < VA30 SP5 or VA40 SP2","status":"affected"}]},{"vendor":"Siemens","product":"SOMATOM go.Sim","versions":[{"version":"All versions < VA30 SP5 or VA40 SP2","status":"affected"}]},{"vendor":"Siemens","product":"SOMATOM go.Top","versions":[{"version":"All versions < VA30 SP5 or VA40 SP2","status":"affected"}]},{"vendor":"Siemens","product":"SOMATOM go.Up","versions":[{"version":"All versions < VA30 SP5 or VA40 SP2","status":"affected"}]},{"vendor":"Siemens","product":"Symbia E/S","versions":[{"version":"All VB22 versions < VB22A-UD03","status":"affected"}]},{"vendor":"Siemens","product":"Symbia Evo","versions":[{"version":"All VB22 versions < VB22A-UD03","status":"affected"}]},{"vendor":"Siemens","product":"Symbia Intevo","versions":[{"version":"All VB22 versions < VB22A-UD03","status":"affected"}]},{"vendor":"Siemens","product":"Symbia T","versions":[{"version":"All VB22 versions < VB22A-UD03","status":"affected"}]},{"vendor":"Siemens","product":"Symbia.net","versions":[{"version":"All VB22 versions < VB22A-UD03","status":"affected"}]},{"vendor":"Siemens","product":"syngo.via VB10","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"syngo.via VB20","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"syngo.via VB30","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"syngo.via VB40","versions":[{"version":"All versions < VB40B HF06","status":"affected"}]},{"vendor":"Siemens","product":"syngo.via VB50","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"syngo.via VB60","versions":[{"version":"All versions < VB60B HF02","status":"affected"}]}],"references":["https://www.siemens-healthineers.com/support-documentation/cybersecurity/shsa-455016"],"weaknesses":["CWE-502"],"ingestedAt":"2026-10-29T19:49:57.813Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2022/29xxx/CVE-2022-29875.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2022-29875","state":"PUBLISHED","datePublished":"2022-06-01T09:50:11.000Z","dateUpdated":"2024-08-03T06:33:42.999Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2022-04-28T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Biograph Horizon PET/CT Systems (All VJ30 versions < VJ30C-UD01), MAGNETOM Family (NUMARIS X: VA12M, VA12S, VA10B, VA20A, VA30A, VA31A), MAMMOMAT Revelation (All VC20 versions < VC20D), NAEOTOM Alpha (All VA40 versions < VA40 SP2), SOMATOM X.cite (All versions < VA30 SP5 or VA40 SP2), SOMATOM X.creed (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.All (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Now (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Open Pro (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Sim (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Top (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Up (All versions < VA30 SP5 or VA40 SP2), Symbia E/S (All VB22 versions < VB22A-UD03), Symbia Evo (All VB22 versions < VB22A-UD03), Symbia Intevo (All VB22 versions < VB22A-UD03), Symbia T (All VB22 versions < VB22A-UD03), Symbia.net (All VB22 versions < VB22A-UD03), syngo.via VB10 (All versions), syngo.via VB20 (All versions), syngo.via VB30 (All versions), syngo.via VB40 (All versions < VB40B HF06), syngo.via VB50 (All versions), syngo.via VB60 (All versions < VB60B HF02). The application deserialises untrusted data without sufficient validations that could result in an arbitrary deserialization. This could allow an unauthenticated attacker to execute code in the affected system if ports 32912/tcp or 32914/tcp are reachable."}],"affected":[{"vendor":"Siemens","product":"Biograph Horizon PET/CT Systems","versions":[{"version":"All VJ30 versions < VJ30C-UD01","status":"affected"}]},{"vendor":"Siemens","product":"MAGNETOM Family","versions":[{"version":"NUMARIS X: VA12M, VA12S, VA10B, VA20A, VA30A, VA31A","status":"affected"}]},{"vendor":"Siemens","product":"MAMMOMAT Revelation","versions":[{"version":"All VC20 versions < VC20D","status":"affected"}]},{"vendor":"Siemens","product":"NAEOTOM Alpha","versions":[{"version":"All VA40 versions < VA40 SP2","status":"affected"}]},{"vendor":"Siemens","product":"SOMATOM X.cite","versions":[{"version":"All versions < VA30 SP5 or VA40 SP2","status":"affected"}]},{"vendor":"Siemens","product":"SOMATOM X.creed","versions":[{"version":"All versions < VA30 SP5 or VA40 SP2","status":"affected"}]},{"vendor":"Siemens","product":"SOMATOM go.All","versions":[{"version":"All versions < VA30 SP5 or VA40 SP2","status":"affected"}]},{"vendor":"Siemens","product":"SOMATOM go.Now","versions":[{"version":"All versions < VA30 SP5 or VA40 SP2","status":"affected"}]},{"vendor":"Siemens","product":"SOMATOM go.Open Pro","versions":[{"version":"All versions < VA30 SP5 or VA40 SP2","status":"affected"}]},{"vendor":"Siemens","product":"SOMATOM go.Sim","versions":[{"version":"All versions < VA30 SP5 or VA40 SP2","status":"affected"}]},{"vendor":"Siemens","product":"SOMATOM go.Top","versions":[{"version":"All versions < VA30 SP5 or VA40 SP2","status":"affected"}]},{"vendor":"Siemens","product":"SOMATOM go.Up","versions":[{"version":"All versions < VA30 SP5 or VA40 SP2","status":"affected"}]},{"vendor":"Siemens","product":"Symbia E/S","versions":[{"version":"All VB22 versions < VB22A-UD03","status":"affected"}]},{"vendor":"Siemens","product":"Symbia Evo","versions":[{"version":"All VB22 versions < VB22A-UD03","status":"affected"}]},{"vendor":"Siemens","product":"Symbia Intevo","versions":[{"version":"All VB22 versions < VB22A-UD03","status":"affected"}]},{"vendor":"Siemens","product":"Symbia T","versions":[{"version":"All VB22 versions < VB22A-UD03","status":"affected"}]},{"vendor":"Siemens","product":"Symbia.net","versions":[{"version":"All VB22 versions < VB22A-UD03","status":"affected"}]},{"vendor":"Siemens","product":"syngo.via VB10","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"syngo.via VB20","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"syngo.via VB30","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"syngo.via VB40","versions":[{"version":"All versions < VB40B HF06","status":"affected"}]},{"vendor":"Siemens","product":"syngo.via VB50","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"syngo.via VB60","versions":[{"version":"All versions < VB60B HF02","status":"affected"}]}],"references":[{"url":"https://www.siemens-healthineers.com/support-documentation/cybersecurity/shsa-455016","tags":["x_refsource_MISC"]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-502","description":"CWE-502: Deserialization of Untrusted Data","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","dateUpdated":"2022-06-01T09:50:10.000Z","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","ID":"CVE-2022-29875","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Biograph Horizon PET/CT Systems","version":{"version_data":[{"version_value":"All VJ30 versions < VJ30C-UD01"}]}},{"product_name":"MAGNETOM Family","version":{"version_data":[{"version_value":"NUMARIS X: VA12M, VA12S, VA10B, VA20A, VA30A, VA31A"}]}},{"product_name":"MAMMOMAT Revelation","version":{"version_data":[{"version_value":"All VC20 versions < VC20D"}]}},{"product_name":"NAEOTOM Alpha","version":{"version_data":[{"version_value":"All VA40 versions < VA40 SP2"}]}},{"product_name":"SOMATOM X.cite","version":{"version_data":[{"version_value":"All versions < VA30 SP5 or VA40 SP2"}]}},{"product_name":"SOMATOM X.creed","version":{"version_data":[{"version_value":"All versions < VA30 SP5 or VA40 SP2"}]}},{"product_name":"SOMATOM go.All","version":{"version_data":[{"version_value":"All versions < VA30 SP5 or VA40 SP2"}]}},{"product_name":"SOMATOM go.Now","version":{"version_data":[{"version_value":"All versions < VA30 SP5 or VA40 SP2"}]}},{"product_name":"SOMATOM go.Open Pro","version":{"version_data":[{"version_value":"All versions < VA30 SP5 or VA40 SP2"}]}},{"product_name":"SOMATOM go.Sim","version":{"version_data":[{"version_value":"All versions < VA30 SP5 or VA40 SP2"}]}},{"product_name":"SOMATOM go.Top","version":{"version_data":[{"version_value":"All versions < VA30 SP5 or VA40 SP2"}]}},{"product_name":"SOMATOM go.Up","version":{"version_data":[{"version_value":"All versions < VA30 SP5 or VA40 SP2"}]}},{"product_name":"Symbia E/S","version":{"version_data":[{"version_value":"All VB22 versions < VB22A-UD03"}]}},{"product_name":"Symbia Evo","version":{"version_data":[{"version_value":"All VB22 versions < VB22A-UD03"}]}},{"product_name":"Symbia Intevo","version":{"version_data":[{"version_value":"All VB22 versions < VB22A-UD03"}]}},{"product_name":"Symbia T","version":{"version_data":[{"version_value":"All VB22 versions < VB22A-UD03"}]}},{"product_name":"Symbia.net","version":{"version_data":[{"version_value":"All VB22 versions < VB22A-UD03"}]}},{"product_name":"syngo.via VB10","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"syngo.via VB20","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"syngo.via VB30","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"syngo.via VB40","version":{"version_data":[{"version_value":"All versions < VB40B HF06"}]}},{"product_name":"syngo.via VB50","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"syngo.via VB60","version":{"version_data":[{"version_value":"All versions < VB60B HF02"}]}}]},"vendor_name":"Siemens"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in Biograph Horizon PET/CT Systems (All VJ30 versions < VJ30C-UD01), MAGNETOM Family (NUMARIS X: VA12M, VA12S, VA10B, VA20A, VA30A, VA31A), MAMMOMAT Revelation (All VC20 versions < VC20D), NAEOTOM Alpha (All VA40 versions < VA40 SP2), SOMATOM X.cite (All versions < VA30 SP5 or VA40 SP2), SOMATOM X.creed (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.All (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Now (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Open Pro (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Sim (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Top (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Up (All versions < VA30 SP5 or VA40 SP2), Symbia E/S (All VB22 versions < VB22A-UD03), Symbia Evo (All VB22 versions < VB22A-UD03), Symbia Intevo (All VB22 versions < VB22A-UD03), Symbia T (All VB22 versions < VB22A-UD03), Symbia.net (All VB22 versions < VB22A-UD03), syngo.via VB10 (All versions), syngo.via VB20 (All versions), syngo.via VB30 (All versions), syngo.via VB40 (All versions < VB40B HF06), syngo.via VB50 (All versions), syngo.via VB60 (All versions < VB60B HF02). The application deserialises untrusted data without sufficient validations that could result in an arbitrary deserialization. This could allow an unauthenticated attacker to execute code in the affected system if ports 32912/tcp or 32914/tcp are reachable."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-502: Deserialization of Untrusted Data"}]}]},"references":{"reference_data":[{"name":"https://www.siemens-healthineers.com/support-documentation/cybersecurity/shsa-455016","refsource":"MISC","url":"https://www.siemens-healthineers.com/support-documentation/cybersecurity/shsa-455016"}]}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://www.siemens-healthineers.com/support-documentation/cybersecurity/shsa-455016","tags":["x_refsource_MISC","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-03T06:33:42.999Z"}}]}}}