{"id":"CVE-2022-29872","state":"PUBLISHED","title":"A vulnerability has been identified in SICAM T (All versions < V3.0). Affected devices do not properly validate parameters of POST requests. This could allow an authenticated attac","description":"A vulnerability has been identified in SICAM T (All versions < V3.0). Affected devices do not properly validate parameters of POST requests. This could allow an authenticated attacker to set the device to a denial of service state or to control the program counter and, thus, execute arbitrary code on the device.","publishedAt":"2022-05-10T09:47:15.000Z","updatedAt":"2025-12-09T10:32:44.196Z","severity":{"score":8.7,"label":"High","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","source":"siemens"},"assigner":"siemens","products":["Siemens SICAM T"],"affected":[{"vendor":"Siemens","product":"SICAM T","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.0","versionType":"custom"}]}],"references":["https://cert-portal.siemens.com/productcert/pdf/ssa-165073.pdf","https://cert-portal.siemens.com/productcert/html/ssa-165073.html","https://cert-portal.siemens.com/productcert/html/ssa-471761.html"],"weaknesses":["CWE-141"],"ingestedAt":"2026-10-29T19:49:57.813Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2022/29xxx/CVE-2022-29872.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2022-29872","state":"PUBLISHED","datePublished":"2022-05-10T09:47:15.000Z","dateUpdated":"2025-12-09T10:32:44.196Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2022-04-28T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SICAM T (All versions < V3.0). Affected devices do not properly validate parameters of POST requests. This could allow an authenticated attacker to set the device to a denial of service state or to control the program counter and, thus, execute arbitrary code on the device."}],"affected":[{"vendor":"Siemens","product":"SICAM T","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.0","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-165073.pdf","tags":["x_refsource_MISC"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-165073.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-471761.html"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","baseScore":8.7,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-141","lang":"en","description":"CWE-141: Improper Neutralization of Parameter/Argument Delimiters","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2025-12-09T10:32:44.196Z"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-165073.pdf","tags":["x_refsource_MISC","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-03T06:33:43.146Z"}}]}}}