{"id":"CVE-2022-29470","state":"PUBLISHED","title":"Improper access control in the Intel® DTT Software before version 8.7.10400.15482 may allow an authenticated user to potentially enable escalation of privilege via local access.","description":"Improper access control in the Intel® DTT Software before version 8.7.10400.15482 may allow an authenticated user to potentially enable escalation of privilege via local access.\n\n","publishedAt":"2023-08-11T02:37:15.254Z","updatedAt":"2024-10-09T17:34:56.961Z","severity":{"score":6.7,"label":"Medium","version":"3.1","vector":"CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H","source":"intel"},"assigner":"intel","products":["n/a Intel DTT Software"],"affected":[{"vendor":"n/a","product":"Intel DTT Software","defaultStatus":"unaffected","versions":[{"version":"before version 8.7.10400.15482","status":"affected"}]}],"references":["http://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00875.html"],"weaknesses":[],"ingestedAt":"2026-10-29T19:49:57.813Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2022/29xxx/CVE-2022-29470.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2022-29470","state":"PUBLISHED","datePublished":"2023-08-11T02:37:15.254Z","dateUpdated":"2024-10-09T17:34:56.961Z","assignerShortName":"intel","assignerOrgId":"6dda929c-bb53-4a77-a76d-48e79601a1ce","dateReserved":"2022-05-11T04:14:45.498Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"Improper access control in the Intel® DTT Software before version 8.7.10400.15482 may allow an authenticated user to potentially enable escalation of privilege via local access.\n\n"}],"affected":[{"vendor":"n/a","product":"Intel DTT Software","defaultStatus":"unaffected","versions":[{"version":"before version 8.7.10400.15482","status":"affected"}]}],"references":[{"url":"http://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00875.html","name":"http://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00875.html"}],"metrics":[{"cvssV3_1":{"attackComplexity":"HIGH","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":6.7,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"description":"escalation of privilege","lang":"en"},{"description":"Improper access control","lang":"en"}]}],"providerMetadata":{"shortName":"intel","orgId":"6dda929c-bb53-4a77-a76d-48e79601a1ce","dateUpdated":"2023-09-22T17:24:27.798Z"},"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"title":"CVE Program Container","references":[{"url":"http://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00875.html","name":"http://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00875.html","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-03T06:26:05.145Z"}},{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-10-09T17:34:47.158480Z","id":"CVE-2022-29470","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-10-09T17:34:56.961Z"}}]}}}