{"id":"CVE-2022-24413","state":"PUBLISHED","title":"Dell PowerScale OneFS, versions 8.2.2-9.3.x, contain a time-of-check-to-time-of-use vulnerability. A local user with access to the filesystem could potentially exploit this vulnera","description":"Dell PowerScale OneFS, versions 8.2.2-9.3.x, contain a time-of-check-to-time-of-use vulnerability. A local user with access to the filesystem could potentially exploit this vulnerability, leading to data loss.","publishedAt":"2022-04-12T17:50:58.945Z","updatedAt":"2024-09-17T04:03:41.224Z","severity":{"score":4.4,"label":"Medium","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L","source":"dell"},"assigner":"dell","products":["Dell PowerScale OneFS"],"affected":[{"vendor":"Dell","product":"PowerScale OneFS","versions":[{"version":"8.2.2-9.3.x","status":"affected"}]}],"references":["https://www.dell.com/support/kbdoc/000196657"],"weaknesses":["CWE-367"],"ingestedAt":"2026-10-29T19:49:43.915Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2022/24xxx/CVE-2022-24413.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2022-24413","state":"PUBLISHED","datePublished":"2022-04-12T17:50:58.945Z","dateUpdated":"2024-09-17T04:03:41.224Z","assignerShortName":"dell","assignerOrgId":"c550e75a-17ff-4988-97f0-544cde3820fe","dateReserved":"2022-02-04T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"Dell PowerScale OneFS, versions 8.2.2-9.3.x, contain a time-of-check-to-time-of-use vulnerability. A local user with access to the filesystem could potentially exploit this vulnerability, leading to data loss."}],"affected":[{"vendor":"Dell","product":"PowerScale OneFS","versions":[{"version":"8.2.2-9.3.x","status":"affected"}]}],"references":[{"url":"https://www.dell.com/support/kbdoc/000196657","tags":["x_refsource_MISC"]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"LOW","baseScore":4.4,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"LOW","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L","version":"3.1"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-367","description":"CWE-367: Time-of-check Time-of-use (TOCTOU) Race Condition","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"dell","dateUpdated":"2022-04-12T17:50:58.000Z","orgId":"c550e75a-17ff-4988-97f0-544cde3820fe"},"datePublic":"2022-03-03T00:00:00.000Z","x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"secure@dell.com","DATE_PUBLIC":"2022-03-03","ID":"CVE-2022-24413","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"PowerScale OneFS","version":{"version_data":[{"version_affected":"=","version_value":"8.2.2-9.3.x"}]}}]},"vendor_name":"Dell"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Dell PowerScale OneFS, versions 8.2.2-9.3.x, contain a time-of-check-to-time-of-use vulnerability. A local user with access to the filesystem could potentially exploit this vulnerability, leading to data loss."}]},"impact":{"cvss":{"baseScore":4.4,"baseSeverity":"Medium","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-367: Time-of-check Time-of-use (TOCTOU) Race Condition"}]}]},"references":{"reference_data":[{"name":"https://www.dell.com/support/kbdoc/000196657","refsource":"MISC","url":"https://www.dell.com/support/kbdoc/000196657"}]}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://www.dell.com/support/kbdoc/000196657","tags":["x_refsource_MISC","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-03T04:13:55.783Z"}}]}}}