{"id":"CVE-2022-22515","state":"PUBLISHED","title":"A component of the CODESYS Control runtime system allows read and write access to configuration files","description":"A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products.","publishedAt":"2022-04-07T18:21:16.280Z","updatedAt":"2024-09-16T17:59:22.215Z","severity":{"score":8.1,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N","source":"CERTVDE"},"assigner":"CERTVDE","products":["CODESYS CODESYS Control RTE (SL)","CODESYS CODESYS Control RTE (for Beckhoff CX) SL","CODESYS CODESYS Control Win (SL)","CODESYS CODESYS HMI (SL)","CODESYS CODESYS Development System V3","CODESYS CODESYS Control Runtime System Toolkit","CODESYS CODESYS Embedded Target Visu Toolkit","CODESYS CODESYS Remote Target Visu Toolkit","CODESYS CODESYS Control for BeagleBone SL","CODESYS CODESYS Control for Beckhoff CX9020 SL","CODESYS CODESYS Control for emPC-A/iMX6 SL","CODESYS CODESYS Control for IOT2000 SL","CODESYS CODESYS Control for Linux SL","CODESYS CODESYS Control for PFC100 SL","CODESYS CODESYS Control for PFC200 SL","CODESYS CODESYS Control for PLCnext SL","CODESYS CODESYS Control for Raspberry Pi SL","CODESYS CODESYS Control for WAGO Touch Panels 600 SL"],"affected":[{"vendor":"CODESYS","product":"CODESYS Control RTE (SL)","versions":[{"version":"V3","status":"affected","lessThan":"V3.5.17.40","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control RTE (for Beckhoff CX) SL","versions":[{"version":"V3","status":"affected","lessThan":"V3.5.17.40","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control Win (SL)","versions":[{"version":"V3","status":"affected","lessThan":"V3.5.17.40","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS HMI (SL)","versions":[{"version":"V3","status":"affected","lessThan":"V3.5.17.40","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Development System V3","versions":[{"version":"V3","status":"affected","lessThan":"V3.5.17.40","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control Runtime System Toolkit","versions":[{"version":"V3","status":"affected","lessThan":"V3.5.17.40","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Embedded Target Visu Toolkit","versions":[{"version":"V3","status":"affected","lessThan":"V3.5.17.40","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Remote Target Visu Toolkit","versions":[{"version":"V3","status":"affected","lessThan":"V3.5.17.40","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for BeagleBone SL","versions":[{"version":"V4","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for Beckhoff CX9020 SL","versions":[{"version":"V4","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for emPC-A/iMX6 SL","versions":[{"version":"V4","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for IOT2000 SL","versions":[{"version":"V4","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for Linux SL","versions":[{"version":"V4","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for PFC100 SL","versions":[{"version":"V4","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for PFC200 SL","versions":[{"version":"V4","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for PLCnext SL","versions":[{"version":"V4","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for Raspberry Pi SL","versions":[{"version":"V4","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for WAGO Touch Panels 600 SL","versions":[{"version":"V4","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]}],"references":["https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=17089&token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53&download="],"weaknesses":["CWE-668"],"ingestedAt":"2026-10-29T19:49:38.433Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2022/22xxx/CVE-2022-22515.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2022-22515","state":"PUBLISHED","datePublished":"2022-04-07T18:21:16.280Z","dateUpdated":"2024-09-16T17:59:22.215Z","assignerShortName":"CERTVDE","assignerOrgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","dateReserved":"2022-01-03T00:00:00.000Z"},"containers":{"cna":{"title":"A component of the CODESYS Control runtime system allows read and write access to configuration files","descriptions":[{"lang":"en","value":"A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products."}],"affected":[{"vendor":"CODESYS","product":"CODESYS Control RTE (SL)","versions":[{"version":"V3","status":"affected","lessThan":"V3.5.17.40","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control RTE (for Beckhoff CX) SL","versions":[{"version":"V3","status":"affected","lessThan":"V3.5.17.40","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control Win (SL)","versions":[{"version":"V3","status":"affected","lessThan":"V3.5.17.40","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS HMI (SL)","versions":[{"version":"V3","status":"affected","lessThan":"V3.5.17.40","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Development System V3","versions":[{"version":"V3","status":"affected","lessThan":"V3.5.17.40","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control Runtime System Toolkit","versions":[{"version":"V3","status":"affected","lessThan":"V3.5.17.40","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Embedded Target Visu Toolkit","versions":[{"version":"V3","status":"affected","lessThan":"V3.5.17.40","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Remote Target Visu Toolkit","versions":[{"version":"V3","status":"affected","lessThan":"V3.5.17.40","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for BeagleBone SL","versions":[{"version":"V4","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for Beckhoff CX9020 SL","versions":[{"version":"V4","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for emPC-A/iMX6 SL","versions":[{"version":"V4","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for IOT2000 SL","versions":[{"version":"V4","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for Linux SL","versions":[{"version":"V4","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for PFC100 SL","versions":[{"version":"V4","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for PFC200 SL","versions":[{"version":"V4","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for PLCnext SL","versions":[{"version":"V4","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for Raspberry Pi SL","versions":[{"version":"V4","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for WAGO Touch Panels 600 SL","versions":[{"version":"V4","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]}],"references":[{"url":"https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=17089&token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53&download=","tags":["x_refsource_CONFIRM"]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":8.1,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N","version":"3.1"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-668","description":"CWE-668 Exposure of Resource to Wrong Sphere","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"CERTVDE","dateUpdated":"2022-05-12T07:45:29.000Z","orgId":"270ccfa6-a436-4e77-922e-914ec3a9685c"},"datePublic":"2022-06-01T00:00:00.000Z","source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.0.9"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"info@cert.vde.com","DATE_PUBLIC":"2022-06-01T10:00:00.000Z","ID":"CVE-2022-22515","STATE":"PUBLIC","TITLE":"A component of the CODESYS Control runtime system allows read and write access to configuration files"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"CODESYS Control RTE (SL)","version":{"version_data":[{"version_affected":"<","version_name":"V3","version_value":"V3.5.17.40"}]}},{"product_name":"CODESYS Control RTE (for Beckhoff CX) SL","version":{"version_data":[{"version_affected":"<","version_name":"V3","version_value":"V3.5.17.40"}]}},{"product_name":"CODESYS Control Win (SL)","version":{"version_data":[{"version_affected":"<","version_name":"V3","version_value":"V3.5.17.40"}]}},{"product_name":"CODESYS HMI (SL)","version":{"version_data":[{"version_affected":"<","version_name":"V3","version_value":"V3.5.17.40"}]}},{"product_name":"CODESYS Development System V3","version":{"version_data":[{"version_affected":"<","version_name":"V3","version_value":"V3.5.17.40"}]}},{"product_name":"CODESYS Control Runtime System Toolkit","version":{"version_data":[{"version_affected":"<","version_name":"V3","version_value":"V3.5.17.40"}]}},{"product_name":"CODESYS Embedded Target Visu Toolkit","version":{"version_data":[{"version_affected":"<","version_name":"V3","version_value":"V3.5.17.40"}]}},{"product_name":"CODESYS Remote Target Visu Toolkit","version":{"version_data":[{"version_affected":"<","version_name":"V3","version_value":"V3.5.17.40"}]}},{"product_name":"CODESYS Control for BeagleBone SL","version":{"version_data":[{"version_affected":"<","version_name":"V4","version_value":"V4.5.0.0"}]}},{"product_name":"CODESYS Control for Beckhoff CX9020 SL","version":{"version_data":[{"version_affected":"<","version_name":"V4","version_value":"V4.5.0.0"}]}},{"product_name":"CODESYS Control for emPC-A/iMX6 SL","version":{"version_data":[{"version_affected":"<","version_name":"V4","version_value":"V4.5.0.0"}]}},{"product_name":"CODESYS Control for IOT2000 SL","version":{"version_data":[{"version_affected":"<","version_name":"V4","version_value":"V4.5.0.0"}]}},{"product_name":"CODESYS Control for Linux SL","version":{"version_data":[{"version_affected":"<","version_name":"V4","version_value":"V4.5.0.0"}]}},{"product_name":"CODESYS Control for PFC100 SL","version":{"version_data":[{"version_affected":"<","version_name":"V4","version_value":"V4.5.0.0"}]}},{"product_name":"CODESYS Control for PFC200 SL","version":{"version_data":[{"version_affected":"<","version_name":"V4","version_value":"V4.5.0.0"}]}},{"product_name":"CODESYS Control for PLCnext SL","version":{"version_data":[{"version_affected":"<","version_name":"V4","version_value":"V4.5.0.0"}]}},{"product_name":"CODESYS Control for Raspberry Pi SL","version":{"version_data":[{"version_affected":"<","version_name":"V4","version_value":"V4.5.0.0"}]}},{"product_name":"CODESYS Control for WAGO Touch Panels 600 SL","version":{"version_data":[{"version_affected":"<","version_name":"V4","version_value":"V4.5.0.0"}]}}]},"vendor_name":"CODESYS"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":8.1,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-668 Exposure of Resource to Wrong Sphere"}]}]},"references":{"reference_data":[{"name":"https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=17089&token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53&download=","refsource":"CONFIRM","url":"https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=17089&token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53&download="}]},"source":{"discovery":"UNKNOWN"}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=17089&token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53&download=","tags":["x_refsource_CONFIRM","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-03T03:14:55.437Z"}}]}}}