{"id":"CVE-2022-22513","state":"PUBLISHED","title":"Null Pointer Dereference in multiple CODESYS products can lead to a DoS.","description":"An authenticated remote attacker can cause a null pointer dereference in the CmpSettings component of the affected CODESYS products which leads to a crash.","publishedAt":"2022-04-07T18:21:12.792Z","updatedAt":"2024-09-17T04:29:14.122Z","severity":{"score":6.5,"label":"Medium","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","source":"CERTVDE"},"assigner":"CERTVDE","products":["CODESYS CODESYS Control RTE (SL)","CODESYS CODESYS Control RTE (for Beckhoff CX) SL","CODESYS CODESYS Control Win (SL)","CODESYS CODESYS Gateway","CODESYS CODESYS Edge Gateway for Windows","CODESYS CODESYS HMI (SL)","CODESYS CODESYS Development System V3","CODESYS CODESYS Control Runtime System Toolkit","CODESYS CODESYS Embedded Target Visu Toolkit","CODESYS CODESYS Remote Target Visu Toolkit","CODESYS CODESYS Control for BeagleBone SL","CODESYS CODESYS Control for Beckhoff CX9020 SL","CODESYS CODESYS Control for emPC-A/iMX6 SL","CODESYS CODESYS Control for IOT2000 SL","CODESYS CODESYS Control for Linux SL","CODESYS CODESYS Control for PFC100 SL","CODESYS CODESYS Control for PFC200 SL","CODESYS CODESYS Control for PLCnext SL","CODESYS CODESYS Control for Raspberry Pi SL","CODESYS CODESYS Control for WAGO Touch Panels 600 SL","CODESYS CODESYS Edge Gateway for Linux"],"affected":[{"vendor":"CODESYS","product":"CODESYS Control RTE (SL)","versions":[{"version":"V3.5.18.0","status":"affected","lessThan":"V3.5.18.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control RTE (for Beckhoff CX) SL","versions":[{"version":"V3.5.18.0","status":"affected","lessThan":"V3.5.18.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control Win (SL)","versions":[{"version":"V3.5.18.0","status":"affected","lessThan":"V3.5.18.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Gateway","versions":[{"version":"V3.5.18.0","status":"affected","lessThan":"V3.5.18.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Edge Gateway for Windows","versions":[{"version":"V3.5.18.0","status":"affected","lessThan":"V3.5.18.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS HMI (SL)","versions":[{"version":"V3.5.18.0","status":"affected","lessThan":"V3.5.18.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Development System V3","versions":[{"version":"V3.5.18.0","status":"affected","lessThan":"V3.5.18.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control Runtime System Toolkit","versions":[{"version":"V3.5.18.0","status":"affected","lessThan":"V3.5.18.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Embedded Target Visu Toolkit","versions":[{"version":"V3.5.18.0","status":"affected","lessThan":"V3.5.18.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Remote Target Visu Toolkit","versions":[{"version":"V3.5.18.0","status":"affected","lessThan":"V3.5.18.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for BeagleBone SL","versions":[{"version":"V4.5.0.0","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for Beckhoff CX9020 SL","versions":[{"version":"V4.5.0.0","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for emPC-A/iMX6 SL","versions":[{"version":"V4.5.0.0","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for IOT2000 SL","versions":[{"version":"V4.5.0.0","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for Linux SL","versions":[{"version":"V4.5.0.0","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for PFC100 SL","versions":[{"version":"V4.5.0.0","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for PFC200 SL","versions":[{"version":"V4.5.0.0","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for PLCnext SL","versions":[{"version":"V4.5.0.0","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for Raspberry Pi SL","versions":[{"version":"V4.5.0.0","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for WAGO Touch Panels 600 SL","versions":[{"version":"V4.5.0.0","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Edge Gateway for Linux","versions":[{"version":"V4.5.0.0","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]}],"references":["https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=17093&token=15cd8424832ea10dcd4873a409a09a539ee381ca&download="],"weaknesses":["CWE-476"],"ingestedAt":"2026-10-29T19:49:38.433Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2022/22xxx/CVE-2022-22513.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2022-22513","state":"PUBLISHED","datePublished":"2022-04-07T18:21:12.792Z","dateUpdated":"2024-09-17T04:29:14.122Z","assignerShortName":"CERTVDE","assignerOrgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","dateReserved":"2022-01-03T00:00:00.000Z"},"containers":{"cna":{"title":"Null Pointer Dereference in multiple CODESYS products can lead to a DoS.","descriptions":[{"lang":"en","value":"An authenticated remote attacker can cause a null pointer dereference in the CmpSettings component of the affected CODESYS products which leads to a crash."}],"affected":[{"vendor":"CODESYS","product":"CODESYS Control RTE (SL)","versions":[{"version":"V3.5.18.0","status":"affected","lessThan":"V3.5.18.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control RTE (for Beckhoff CX) SL","versions":[{"version":"V3.5.18.0","status":"affected","lessThan":"V3.5.18.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control Win (SL)","versions":[{"version":"V3.5.18.0","status":"affected","lessThan":"V3.5.18.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Gateway","versions":[{"version":"V3.5.18.0","status":"affected","lessThan":"V3.5.18.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Edge Gateway for Windows","versions":[{"version":"V3.5.18.0","status":"affected","lessThan":"V3.5.18.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS HMI (SL)","versions":[{"version":"V3.5.18.0","status":"affected","lessThan":"V3.5.18.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Development System V3","versions":[{"version":"V3.5.18.0","status":"affected","lessThan":"V3.5.18.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control Runtime System Toolkit","versions":[{"version":"V3.5.18.0","status":"affected","lessThan":"V3.5.18.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Embedded Target Visu Toolkit","versions":[{"version":"V3.5.18.0","status":"affected","lessThan":"V3.5.18.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Remote Target Visu Toolkit","versions":[{"version":"V3.5.18.0","status":"affected","lessThan":"V3.5.18.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for BeagleBone SL","versions":[{"version":"V4.5.0.0","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for Beckhoff CX9020 SL","versions":[{"version":"V4.5.0.0","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for emPC-A/iMX6 SL","versions":[{"version":"V4.5.0.0","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for IOT2000 SL","versions":[{"version":"V4.5.0.0","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for Linux SL","versions":[{"version":"V4.5.0.0","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for PFC100 SL","versions":[{"version":"V4.5.0.0","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for PFC200 SL","versions":[{"version":"V4.5.0.0","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for PLCnext SL","versions":[{"version":"V4.5.0.0","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for Raspberry Pi SL","versions":[{"version":"V4.5.0.0","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Control for WAGO Touch Panels 600 SL","versions":[{"version":"V4.5.0.0","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]},{"vendor":"CODESYS","product":"CODESYS Edge Gateway for Linux","versions":[{"version":"V4.5.0.0","status":"affected","lessThan":"V4.5.0.0","versionType":"custom"}]}],"references":[{"url":"https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=17093&token=15cd8424832ea10dcd4873a409a09a539ee381ca&download=","tags":["x_refsource_MISC"]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":6.5,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","version":"3.1"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-476","description":"CWE-476 NULL Pointer Dereference","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"CERTVDE","dateUpdated":"2022-04-27T05:55:10.000Z","orgId":"270ccfa6-a436-4e77-922e-914ec3a9685c"},"datePublic":"2022-04-06T00:00:00.000Z","source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.0.9"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"info@cert.vde.com","DATE_PUBLIC":"2022-04-06T10:00:00.000Z","ID":"CVE-2022-22513","STATE":"PUBLIC","TITLE":"Null Pointer Dereference in multiple CODESYS products can lead to a DoS."},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"CODESYS Control RTE (SL)","version":{"version_data":[{"version_affected":"<","version_name":"V3.5.18.0","version_value":"V3.5.18.0"}]}},{"product_name":"CODESYS Control RTE (for Beckhoff CX) SL","version":{"version_data":[{"version_affected":"<","version_name":"V3.5.18.0","version_value":"V3.5.18.0"}]}},{"product_name":"CODESYS Control Win (SL)","version":{"version_data":[{"version_affected":"<","version_name":"V3.5.18.0","version_value":"V3.5.18.0"}]}},{"product_name":"CODESYS Gateway","version":{"version_data":[{"version_affected":"<","version_name":"V3.5.18.0","version_value":"V3.5.18.0"}]}},{"product_name":"CODESYS Edge Gateway for Windows","version":{"version_data":[{"version_affected":"<","version_name":"V3.5.18.0","version_value":"V3.5.18.0"}]}},{"product_name":"CODESYS HMI (SL)","version":{"version_data":[{"version_affected":"<","version_name":"V3.5.18.0","version_value":"V3.5.18.0"}]}},{"product_name":"CODESYS Development System V3","version":{"version_data":[{"version_affected":"<","version_name":"V3.5.18.0","version_value":"V3.5.18.0"}]}},{"product_name":"CODESYS Control Runtime System Toolkit","version":{"version_data":[{"version_affected":"<","version_name":"V3.5.18.0","version_value":"V3.5.18.0"}]}},{"product_name":"CODESYS Embedded Target Visu Toolkit","version":{"version_data":[{"version_affected":"<","version_name":"V3.5.18.0","version_value":"V3.5.18.0"}]}},{"product_name":"CODESYS Remote Target Visu Toolkit","version":{"version_data":[{"version_affected":"<","version_name":"V3.5.18.0","version_value":"V3.5.18.0"}]}},{"product_name":"CODESYS Control for BeagleBone SL","version":{"version_data":[{"version_affected":"<","version_name":"V4.5.0.0","version_value":"V4.5.0.0"}]}},{"product_name":"CODESYS Control for Beckhoff CX9020 SL","version":{"version_data":[{"version_affected":"<","version_name":"V4.5.0.0","version_value":"V4.5.0.0"}]}},{"product_name":"CODESYS Control for emPC-A/iMX6 SL","version":{"version_data":[{"version_affected":"<","version_name":"V4.5.0.0","version_value":"V4.5.0.0"}]}},{"product_name":"CODESYS Control for IOT2000 SL","version":{"version_data":[{"version_affected":"<","version_name":"V4.5.0.0","version_value":"V4.5.0.0"}]}},{"product_name":"CODESYS Control for Linux SL","version":{"version_data":[{"version_affected":"<","version_name":"V4.5.0.0","version_value":"V4.5.0.0"}]}},{"product_name":"CODESYS Control for PFC100 SL","version":{"version_data":[{"version_affected":"<","version_name":"V4.5.0.0","version_value":"V4.5.0.0"}]}},{"product_name":"CODESYS Control for PFC200 SL","version":{"version_data":[{"version_affected":"<","version_name":"V4.5.0.0","version_value":"V4.5.0.0"}]}},{"product_name":"CODESYS Control for PLCnext SL","version":{"version_data":[{"version_affected":"<","version_name":"V4.5.0.0","version_value":"V4.5.0.0"}]}},{"product_name":"CODESYS Control for Raspberry Pi SL","version":{"version_data":[{"version_affected":"<","version_name":"V4.5.0.0","version_value":"V4.5.0.0"}]}},{"product_name":"CODESYS Control for WAGO Touch Panels 600 SL","version":{"version_data":[{"version_affected":"<","version_name":"V4.5.0.0","version_value":"V4.5.0.0"}]}},{"product_name":"CODESYS Edge Gateway for Linux","version":{"version_data":[{"version_affected":"<","version_name":"V4.5.0.0","version_value":"V4.5.0.0"}]}}]},"vendor_name":"CODESYS"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An authenticated remote attacker can cause a null pointer dereference in the CmpSettings component of the affected CODESYS products which leads to a crash."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":6.5,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-476 NULL Pointer Dereference"}]}]},"references":{"reference_data":[{"name":"https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=17093&token=15cd8424832ea10dcd4873a409a09a539ee381ca&download=","refsource":"MISC","url":"https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=17093&token=15cd8424832ea10dcd4873a409a09a539ee381ca&download="}]},"source":{"discovery":"UNKNOWN"}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=17093&token=15cd8424832ea10dcd4873a409a09a539ee381ca&download=","tags":["x_refsource_MISC","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-03T03:14:55.460Z"}}]}}}