{"id":"CVE-2022-0815","state":"PUBLISHED","title":"McAfee WebAdvisor - Extension Fingerprinting vulnerability","description":"Improper access control vulnerability in McAfee WebAdvisor Chrome and Edge browser extensions up to 8.1.0.1895 allows a remote attacker to gain access to McAfee WebAdvisor settings and other details about the user’s system. This could lead to unexpected behaviors including; settings being changed, fingerprinting of the system leading to targeted scams, and not triggering the malicious software if McAfee software is detected.","publishedAt":"2022-03-10T22:30:11.000Z","updatedAt":"2024-08-02T23:40:04.354Z","severity":{"score":6.5,"label":"Medium","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L","source":"trellix"},"assigner":"trellix","products":["McAfee McAfee WebAdvisor"],"affected":[{"vendor":"McAfee","product":"McAfee WebAdvisor","versions":[{"version":"unspecified","status":"affected","lessThanOrEqual":"8.1.0.1895","versionType":"custom"}]}],"references":["https://service.mcafee.com/?articleId=TS103273&page=shell&shell=article-view"],"weaknesses":["CWE-668"],"ingestedAt":"2026-10-29T19:49:26.075Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2022/0xxx/CVE-2022-0815.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2022-0815","state":"PUBLISHED","datePublished":"2022-03-10T22:30:11.000Z","dateUpdated":"2024-08-02T23:40:04.354Z","assignerShortName":"trellix","assignerOrgId":"01626437-bf8f-4d1c-912a-893b5eb04808","dateReserved":"2022-03-01T00:00:00.000Z"},"containers":{"cna":{"title":"McAfee WebAdvisor - Extension Fingerprinting vulnerability","descriptions":[{"lang":"en","value":"Improper access control vulnerability in McAfee WebAdvisor Chrome and Edge browser extensions up to 8.1.0.1895 allows a remote attacker to gain access to McAfee WebAdvisor settings and other details about the user’s system. This could lead to unexpected behaviors including; settings being changed, fingerprinting of the system leading to targeted scams, and not triggering the malicious software if McAfee software is detected."}],"affected":[{"vendor":"McAfee","product":"McAfee WebAdvisor","versions":[{"version":"unspecified","status":"affected","lessThanOrEqual":"8.1.0.1895","versionType":"custom"}]}],"references":[{"url":"https://service.mcafee.com/?articleId=TS103273&page=shell&shell=article-view","tags":["x_refsource_MISC"]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"LOW","baseScore":6.5,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L","version":"3.1"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-668","description":"CWE-668: Exposure of Resource to Wrong Sphere","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"trellix","dateUpdated":"2022-03-10T22:30:11.000Z","orgId":"01626437-bf8f-4d1c-912a-893b5eb04808"},"source":{"advisory":"TS103273","discovery":"EXTERNAL"},"x_generator":{"engine":"Vulnogram 0.0.9"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"psirt@mcafee.com","ID":"CVE-2022-0815","STATE":"PUBLIC","TITLE":"McAfee WebAdvisor - Extension Fingerprinting vulnerability"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"McAfee WebAdvisor","version":{"version_data":[{"version_affected":"<=","version_value":"8.1.0.1895"}]}}]},"vendor_name":"McAfee"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Improper access control vulnerability in McAfee WebAdvisor Chrome and Edge browser extensions up to 8.1.0.1895 allows a remote attacker to gain access to McAfee WebAdvisor settings and other details about the user’s system. This could lead to unexpected behaviors including; settings being changed, fingerprinting of the system leading to targeted scams, and not triggering the malicious software if McAfee software is detected."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"LOW","baseScore":6.5,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-668: Exposure of Resource to Wrong Sphere"}]}]},"references":{"reference_data":[{"name":"https://service.mcafee.com/?articleId=TS103273&page=shell&shell=article-view","refsource":"MISC","url":"https://service.mcafee.com/?articleId=TS103273&page=shell&shell=article-view"}]},"source":{"advisory":"TS103273","discovery":"EXTERNAL"}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://service.mcafee.com/?articleId=TS103273&page=shell&shell=article-view","tags":["x_refsource_MISC","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-02T23:40:04.354Z"}}]}}}