{"id":"CVE-2021-43937","state":"PUBLISHED","title":"Elcomplus SmartPTT SCADA Server Cross-site Request Forgery","description":"Elcomplus SmartPTT SCADA Server web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request.","publishedAt":"2022-04-29T15:17:35.000Z","updatedAt":"2025-04-16T16:27:36.910Z","severity":{"score":7.6,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L","source":"icscert"},"assigner":"icscert","products":["Elcomplus SmartPTT SCADA Server"],"affected":[{"vendor":"Elcomplus","product":"SmartPTT SCADA Server","versions":[{"version":"1.4","status":"affected"}]}],"references":["https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-05"],"weaknesses":["CWE-200"],"ingestedAt":"2026-10-29T19:49:07.642Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2021/43xxx/CVE-2021-43937.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2021-43937","state":"PUBLISHED","datePublished":"2022-04-29T15:17:35.000Z","dateUpdated":"2025-04-16T16:27:36.910Z","assignerShortName":"icscert","assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","dateReserved":"2021-11-16T00:00:00.000Z"},"containers":{"cna":{"title":"Elcomplus SmartPTT SCADA Server Cross-site Request Forgery","descriptions":[{"lang":"en","value":"Elcomplus SmartPTT SCADA Server web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request."}],"affected":[{"vendor":"Elcomplus","product":"SmartPTT SCADA Server","versions":[{"version":"1.4","status":"affected"}]}],"references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-05","tags":["x_refsource_CONFIRM"]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"LOW","baseScore":7.6,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"LOW","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L","version":"3.1"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-200","description":"CWE-200 Information Exposure","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"icscert","dateUpdated":"2022-04-29T15:17:35.000Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6"},"credits":[{"lang":"en","value":"Michael Heinzl reported these vulnerabilities to CISA."}],"solutions":[{"lang":"en","value":"Elcomplus has released an update to fix these vulnerabilities and recommends users upgrade to Version 2.3.4 or later.\n\nFor more information, please contact Elcomplus support."}],"source":{"advisory":"ICSA-22-109-05","discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.0.9"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2021-43937","STATE":"PUBLIC","TITLE":"Elcomplus SmartPTT SCADA Server Cross-site Request Forgery"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"SmartPTT SCADA Server","version":{"version_data":[{"version_affected":"=","version_value":"1.4"}]}}]},"vendor_name":"Elcomplus"}]}},"credit":[{"lang":"eng","value":"Michael Heinzl reported these vulnerabilities to CISA."}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Elcomplus SmartPTT SCADA Server web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"LOW","baseScore":7.6,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"LOW","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-200 Information Exposure"}]}]},"references":{"reference_data":[{"name":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-05","refsource":"CONFIRM","url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-05"}]},"solution":[{"lang":"en","value":"Elcomplus has released an update to fix these vulnerabilities and recommends users upgrade to Version 2.3.4 or later.\n\nFor more information, please contact Elcomplus support."}],"source":{"advisory":"ICSA-22-109-05","discovery":"UNKNOWN"}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-05","tags":["x_refsource_CONFIRM","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-04T04:10:17.001Z"}},{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-04-16T15:53:11.629914Z","id":"CVE-2021-43937","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-04-16T16:27:36.910Z"}}]}}}