{"id":"CVE-2021-36203","state":"PUBLISHED","title":"Johnson Controls Metasys SCT Pro","description":"The affected product may allow an attacker to identify and forge requests to internal systems by way of a specially crafted request.","publishedAt":"2022-04-22T14:44:10.638Z","updatedAt":"2024-09-17T02:12:16.472Z","severity":{"score":5.3,"label":"Medium","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","source":"jci"},"assigner":"jci","products":["Johnnson Controls Metasys System Configuration Tool (SCT)","Johnnson Controls Metasys System Configuration Tool Pro (SCT Pro)"],"affected":[{"vendor":"Johnnson Controls","product":"Metasys System Configuration Tool (SCT)","versions":[{"version":"All","status":"affected","lessThan":"14.2.2","versionType":"custom"}]},{"vendor":"Johnnson Controls","product":"Metasys System Configuration Tool Pro (SCT Pro)","versions":[{"version":"All","status":"affected","lessThan":"14.2.2","versionType":"custom"}]}],"references":["https://www.cisa.gov/uscert/ics/advisories/icsa-22-111-02"],"weaknesses":["CWE-918"],"ingestedAt":"2026-10-29T19:48:44.655Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2021/36xxx/CVE-2021-36203.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2021-36203","state":"PUBLISHED","datePublished":"2022-04-22T14:44:10.638Z","dateUpdated":"2024-09-17T02:12:16.472Z","assignerShortName":"jci","assignerOrgId":"7281d04a-a537-43df-bfb4-fa4110af9d01","dateReserved":"2021-07-06T00:00:00.000Z"},"containers":{"cna":{"title":"Johnson Controls Metasys SCT Pro","descriptions":[{"lang":"en","value":"The affected product may allow an attacker to identify and forge requests to internal systems by way of a specially crafted request."}],"affected":[{"vendor":"Johnnson Controls","product":"Metasys System Configuration Tool (SCT)","versions":[{"version":"All","status":"affected","lessThan":"14.2.2","versionType":"custom"}]},{"vendor":"Johnnson Controls","product":"Metasys System Configuration Tool Pro (SCT Pro)","versions":[{"version":"All","status":"affected","lessThan":"14.2.2","versionType":"custom"}]}],"references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-111-02","tags":["x_refsource_MISC"]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":5.3,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-918","description":"CWE-918 Server-Side Request Forgery (SSRF)","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"jci","dateUpdated":"2022-05-03T19:29:50.000Z","orgId":"7281d04a-a537-43df-bfb4-fa4110af9d01"},"credits":[{"lang":"en","value":"Tony West and Scott Ponte reported this vulnerability to Johnson Controls. Johnson Controls reported this vulnerability to CISA."}],"datePublic":"2022-04-21T00:00:00.000Z","solutions":[{"lang":"en","value":"Johnson Controls recommends users take the following steps to mitigate this vulnerability:\n\nUpdate SCT/SCT Pro with Patch 14.2.2\nTake proper steps to minimize risks to all building automation systems.\nFor more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2022-03 v1"}],"source":{"advisory":"ICSA-22-111-02","discovery":"EXTERNAL"},"x_generator":{"engine":"Vulnogram 0.0.9"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"productsecurity@jci.com","DATE_PUBLIC":"2022-04-21T17:00:00.000Z","ID":"CVE-2021-36203","STATE":"PUBLIC","TITLE":"Johnson Controls Metasys SCT Pro"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Metasys System Configuration Tool (SCT)","version":{"version_data":[{"version_affected":"<","version_name":"All","version_value":"14.2.2"}]}},{"product_name":"Metasys System Configuration Tool Pro (SCT Pro)","version":{"version_data":[{"version_affected":"<","version_name":"All","version_value":"14.2.2"}]}}]},"vendor_name":"Johnnson Controls"}]}},"credit":[{"lang":"eng","value":"Tony West and Scott Ponte reported this vulnerability to Johnson Controls. Johnson Controls reported this vulnerability to CISA."}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"The affected product may allow an attacker to identify and forge requests to internal systems by way of a specially crafted request."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":5.3,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-918 Server-Side Request Forgery (SSRF)"}]}]},"references":{"reference_data":[{"name":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-111-02","refsource":"MISC","url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-111-02"}]},"solution":[{"lang":"en","value":"Johnson Controls recommends users take the following steps to mitigate this vulnerability:\n\nUpdate SCT/SCT Pro with Patch 14.2.2\nTake proper steps to minimize risks to all building automation systems.\nFor more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2022-03 v1"}],"source":{"advisory":"ICSA-22-111-02","discovery":"EXTERNAL"}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-111-02","tags":["x_refsource_MISC","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-04T00:54:50.703Z"}}]}}}