{"id":"CVE-2021-34576","state":"PUBLISHED","title":"Observable discrepancy in Kaden PICOFLUX AiR leaks water consumption","description":"In Kaden PICOFLUX Air in all known versions an information exposure through observable discrepancy exists. This may give sensitive information (water consumption without distinct values) to third parties.","publishedAt":"2021-09-16T12:20:19.792Z","updatedAt":"2024-09-17T02:31:17.646Z","severity":{"score":4.3,"label":"Medium","version":"3.1","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","source":"CERTVDE"},"assigner":"CERTVDE","products":["Kaden PICOFLUX AiR"],"affected":[{"vendor":"Kaden","product":"PICOFLUX AiR","versions":[{"version":"all","status":"affected"}]}],"references":["https://www.fit.vutbr.cz/~polcak/CVE-2021-34576.en"],"weaknesses":["CWE-203"],"ingestedAt":"2026-10-29T19:48:38.863Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2021/34xxx/CVE-2021-34576.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2021-34576","state":"PUBLISHED","datePublished":"2021-09-16T12:20:19.792Z","dateUpdated":"2024-09-17T02:31:17.646Z","assignerShortName":"CERTVDE","assignerOrgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","dateReserved":"2021-06-10T00:00:00.000Z"},"containers":{"cna":{"title":"Observable discrepancy in Kaden PICOFLUX AiR leaks water consumption","descriptions":[{"lang":"en","value":"In Kaden PICOFLUX Air in all known versions an information exposure through observable discrepancy exists. This may give sensitive information (water consumption without distinct values) to third parties."}],"affected":[{"vendor":"Kaden","product":"PICOFLUX AiR","versions":[{"version":"all","status":"affected"}]}],"references":[{"url":"https://www.fit.vutbr.cz/~polcak/CVE-2021-34576.en","tags":["x_refsource_CONFIRM"]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"ADJACENT_NETWORK","availabilityImpact":"NONE","baseScore":4.3,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-203","description":"CWE-203 Information Exposure Through Discrepancy","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"CERTVDE","dateUpdated":"2021-09-16T12:20:19.000Z","orgId":"270ccfa6-a436-4e77-922e-914ec3a9685c"},"credits":[{"lang":"en","value":"Libor POLČÁK reported to CERT@VDE"}],"datePublic":"2021-08-31T00:00:00.000Z","source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.0.9"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"info@cert.vde.com","DATE_PUBLIC":"2021-08-31T22:00:00.000Z","ID":"CVE-2021-34576","STATE":"PUBLIC","TITLE":"Observable discrepancy in Kaden PICOFLUX AiR leaks water consumption"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"PICOFLUX AiR","version":{"version_data":[{"version_value":"all"}]}}]},"vendor_name":"Kaden"}]}},"credit":[{"lang":"eng","value":"Libor POLČÁK reported to CERT@VDE"}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"In Kaden PICOFLUX Air in all known versions an information exposure through observable discrepancy exists. This may give sensitive information (water consumption without distinct values) to third parties."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"ADJACENT_NETWORK","availabilityImpact":"NONE","baseScore":4.3,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-203 Information Exposure Through Discrepancy"}]}]},"references":{"reference_data":[{"name":"https://www.fit.vutbr.cz/~polcak/CVE-2021-34576.en","refsource":"CONFIRM","url":"https://www.fit.vutbr.cz/~polcak/CVE-2021-34576.en"}]},"source":{"discovery":"UNKNOWN"}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://www.fit.vutbr.cz/~polcak/CVE-2021-34576.en","tags":["x_refsource_CONFIRM","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-04T00:19:47.029Z"}}]}}}