{"id":"CVE-2021-33841","state":"PUBLISHED","title":"Circutor SGE-PLC1000 OS command Injection","description":"SGE-PLC1000 device, in its 0.9.2b firmware version, does not handle some requests correctly, allowing a remote attacker to inject code into the operating system with maximum privileges.","publishedAt":"2021-06-09T11:50:24.638Z","updatedAt":"2024-09-16T17:59:08.672Z","severity":{"score":10,"label":"Critical","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H","source":"INCIBE"},"assigner":"INCIBE","products":["Circutor SGE-PLC1000"],"affected":[{"vendor":"Circutor","product":"SGE-PLC1000","defaultStatus":"unaffected","versions":[{"version":"0.9.2b","status":"affected"}]}],"references":["https://www.incibe.es/en/incibe-cert/notices/aviso-sci/circutor-sge-plc1000-os-command-injection"],"weaknesses":["CWE-78"],"ingestedAt":"2026-10-29T19:48:36.050Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2021/33xxx/CVE-2021-33841.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2021-33841","state":"PUBLISHED","datePublished":"2021-06-09T11:50:24.638Z","dateUpdated":"2024-09-16T17:59:08.672Z","assignerShortName":"INCIBE","assignerOrgId":"0cbda920-cd7f-484a-8e76-bf7f4b7f4516","dateReserved":"2021-06-04T00:00:00.000Z"},"containers":{"cna":{"title":"Circutor SGE-PLC1000 OS command Injection","descriptions":[{"lang":"en","value":"SGE-PLC1000 device, in its 0.9.2b firmware version, does not handle some requests correctly, allowing a remote attacker to inject code into the operating system with maximum privileges."}],"affected":[{"vendor":"Circutor","product":"SGE-PLC1000","defaultStatus":"unaffected","versions":[{"version":"0.9.2b","status":"affected"}]}],"references":[{"url":"https://www.incibe.es/en/incibe-cert/notices/aviso-sci/circutor-sge-plc1000-os-command-injection","tags":["x_refsource_CONFIRM"]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":10,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-78","description":"CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"INCIBE","orgId":"0cbda920-cd7f-484a-8e76-bf7f4b7f4516","dateUpdated":"2023-11-22T12:26:06.361Z"},"credits":[{"lang":"en","type":"finder","user":"00000000-0000-4000-9000-000000000000","value":"Industrial Cybersecurity team of S21sec, special mention to Aarón Flecha Menéndez."}],"datePublic":"2021-06-07T22:00:00.000Z","solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"This issue can be solved through a firmware upgrade that has already been released by the vendor."}],"value":"This issue can be solved through a firmware upgrade that has already been released by the vendor."}],"source":{"advisory":"INCIBE-2021-0227","discovery":"EXTERNAL"},"x_generator":{"engine":"Vulnogram 0.0.9"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cve-coordination@incibe.es","DATE_PUBLIC":"2021-06-08T08:00:00.000Z","ID":"CVE-2021-33841","STATE":"PUBLIC","TITLE":"Circutor SGE-PLC1000 OS command Injection"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"SGE-PLC1000","version":{"version_data":[{"version_affected":"=","version_name":"0.9.2b","version_value":"0.9.2b"}]}}]},"vendor_name":"Circutor"}]}},"credit":[{"lang":"eng","value":"Industrial Cybersecurity team of S21sec, special mention to Aarón Flecha Menéndez."}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"SGE-PLC1000 device, in its 0.9.2b firmware version, does not handle some requests correctly, allowing a remote attacker to inject code into the operating system with maximum privileges."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"ADJACENT_NETWORK","availabilityImpact":"HIGH","baseScore":9.6,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')"}]}]},"references":{"reference_data":[{"name":"https://www.incibe-cert.es/en/early-warning/ics-advisories/circutor-sge-plc1000-os-command-injection","refsource":"CONFIRM","url":"https://www.incibe-cert.es/en/early-warning/ics-advisories/circutor-sge-plc1000-os-command-injection"}]},"solution":[{"lang":"en","value":"This issue can be solved through a firmware upgrade that has already been released by the vendor."}],"source":{"advisory":"INCIBE-2021-0227","discovery":"EXTERNAL"}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://www.incibe.es/en/incibe-cert/notices/aviso-sci/circutor-sge-plc1000-os-command-injection","tags":["x_refsource_CONFIRM","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-03T23:58:23.191Z"}}]}}}