{"id":"CVE-2021-33722","state":"PUBLISHED","title":"A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). The affected system has a Path Traversal vulnerability when exporting a firmware container. Wit","description":"A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). The affected system has a Path Traversal vulnerability when exporting a firmware container. With this a privileged authenticated attacker could create arbitrary files on an affected system.","publishedAt":"2021-10-12T09:49:23.000Z","updatedAt":"2024-08-03T23:58:22.756Z","severity":null,"assigner":"siemens","products":["Siemens SINEC NMS"],"affected":[{"vendor":"Siemens","product":"SINEC NMS","versions":[{"version":"All versions < V1.0 SP2 Update 1","status":"affected"}]}],"references":["https://cert-portal.siemens.com/productcert/pdf/ssa-163251.pdf"],"weaknesses":["CWE-22"],"ingestedAt":"2026-10-29T19:48:36.050Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2021/33xxx/CVE-2021-33722.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2021-33722","state":"PUBLISHED","datePublished":"2021-10-12T09:49:23.000Z","dateUpdated":"2024-08-03T23:58:22.756Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2021-05-28T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). The affected system has a Path Traversal vulnerability when exporting a firmware container. With this a privileged authenticated attacker could create arbitrary files on an affected system."}],"affected":[{"vendor":"Siemens","product":"SINEC NMS","versions":[{"version":"All versions < V1.0 SP2 Update 1","status":"affected"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-163251.pdf","tags":["x_refsource_MISC"]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-22","description":"CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","dateUpdated":"2021-10-12T09:49:23.000Z","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","ID":"CVE-2021-33722","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"SINEC NMS","version":{"version_data":[{"version_value":"All versions < V1.0 SP2 Update 1"}]}}]},"vendor_name":"Siemens"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). The affected system has a Path Traversal vulnerability when exporting a firmware container. With this a privileged authenticated attacker could create arbitrary files on an affected system."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')"}]}]},"references":{"reference_data":[{"name":"https://cert-portal.siemens.com/productcert/pdf/ssa-163251.pdf","refsource":"MISC","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-163251.pdf"}]}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-163251.pdf","tags":["x_refsource_MISC","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-03T23:58:22.756Z"}}]}}}